Settings And Operation [S-Servoii Mini]; Drive Status Led; Resolution Setting Switch(Sw1.1~Sw1.4) - Fastech S-SERVOII Operating Manual

Stepping motor control system
Table of Contents

Advertisement

22. Settings and Operation [S-SERVOII MINI]

22.1 Drive Status LED

Indication Color
PWR
Green Power input indication
INP
Yellow Complete Positioning Motion
EN
Orange Motor Enable Status
ALM
Red
Alarm indication
◆ Protection functions and LED flash times
Times
Protection
1
Over Current Error
2
Over Speed Error
3
Position Tracking Error
4
Over Load Error
5
Over Temperature Error
6
Over Regeneratived Voltage Error Back-EMF more than 48V
7
Motor Connect Error
8
Encoder Connect Error
10
In-Position Error
12
ROM Error
15
Position Overflow Error

22.2 Resolution Setting Switch(SW1.1~SW1.4)

The Number of pulse per revolution.
Position
1
2
3
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
*1 : In case of products with an encoder resolution of 16,000, the corresponding pulse/rotation is 16,000.
www.fastech.co.kr - 34
Drive status LED
Input/Output signal
connection(CN1)
Encoder connection(CN2)
Motor connection(CN3)
Power connection(CN4)
Function
LED is turned ON when power is applied
Light on when Position Deviation located within
preset value
Command Pulse Input is completed
Enable: Lights On, Disable: Lights Off
Flash when protection function is activated
(Identifiable which protection mode is activated
by counting the blinking times)
The current through power devices in drive exceeds 4.8A
Motor speed exceed 3,000 [rpm]
Position error value is higher than 180 ˚in motor run state
The motor is continuously operated more than 5 second under a load
exceeding the max. torque
Inside temperature of drive exceeds 85℃
The power is ON without connection of the motor cable to drive
Cable connection error in Encoder connection of drive
After operation is finished, position error more than 1 pulse is contin-
ued for more than 3 seconds
Error occurs in parameter storage device(ROM)
Position error value is higher than 180 ˚in motor stop state
Pulse/Revolution
4
ON
500
OFF
1,000
ON
1,600
OFF
2,000
ON
3,200
OFF
3,600
ON
4,000
OFF
5,000
Parameter setting
connection(CN5)
ON/OFF Condition
from target position, after Position
*1
Conditions
Position
1
2
3
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
Resolution setting switch(SW1.1~1.4)
Direction setting switch(SW1.5)
Pulse input setting switch(SW1.6)
*1 : Default = 0
Can be selected by parameter
setting GUI
Pulse/Revolution
4
ON
6,400
OFF
8,000
ON
10,000
OFF
20,000
ON
25,000
OFF
36,000
ON
40,000
OFF
50,000
*1

Advertisement

Table of Contents
loading

Table of Contents