2
Circulation fan
Picture may vary somewhat from the equip-
ment on your caravan!
87
• If the flame extinguishes again, re-ignition takes place during
1
the closing phase of the fusible cut-out of the ignition safety
switch (approx. 30 seconds).
• If no flame is ignited, the automatic ignitor k will continue to
work until the operation handle
To shut off:
• Turn the operation handle
ignitor is thereby shut off.
• Close the bottle valve and the quick-close valve if the unit is
not used for a longer period of time.
Changing batteries on the automatic ignitor
If you cannot hear any ignition sparks or only hear them in inter-
vals of more than one second, then you must insert a new battery.
• Ensure that the heating has been switched off.
• Remove the radiator cover (see Truma oper-ating instructions).
• Push the cover of the battery compartment up and exchange
the battery (take special note of plus and minus).
• Close the battery compartment.
• Use only a temperature-resistant (+70° C) and leakproof mi-
gnon battery.
Insert new batteries before the beginning of each
heating season.
Also note the separate operating instructions from
the manufacturer.
The heater in your caravan is equipped with a circulation fan. It
1
circulates the hot air throughout the interior of the caravan.
Operation
The efficiency of the fan can be regulated by means of the switch
integrated in the reflecting panel of the heater
the external switch that is located near the heater.
j
is switched to "0".
j
to position "0". The automatic
j
or by means of
9. Gas