Pin assignment for the switch box
Pin name
Assignment
S2
Earth from power supply
S1
12 V from power supply
S41
2 x earth and 2 x plus from battery 9/13
Earth and plus to charging controller for rally package
S38
Earth and plus to charging controller for rally package
S39
S40
Earth and plus 10/11 for rally package
A1
Earth and plus (water pump)
A2
Earth and plus (Porta Potti toilet)
A3
Earth and plus (12V, plug sockets)
A4
Earth and plus
B2
Earth and plus (antenna)
B3
Earth and plus (combi heating or circulation fan)
B4
Earth and plus (circulation fan)
B5
Earth and plus + steady plus (radio)
B6
Earth and steady plus (Wi-Fi)
B7
Earth and steady plus (Tec-Tower)
B8
Earth and steady plus
C1
Earth and plus (lighting in living room)
C2
Earth and plus (lighting in kitchen)
C3
Earth and plus
D1
Earth and 2 x plus for ceiling light in bedroom
D2a= plus upper LED strip overhead stowage compartment
D2
D3a= plus lower LED strip overhead stowage compartment and lighting for corner shelf
Earth and plus
D2b
Earth and plus LED strip
D3b
Earth and plus LED strip superstructure
D5
Earth and plus
E1
Earth and 2 x plus for ceiling lights in living room
E2a = plus upper LED strip overhead stowage compartment
E2
E3a= lower LED strip overhead stowage compartment and lighting for corner shelf
Earth and plus
E2b
Earth and plus upper LED strip overhead stowage compartment
Earth and plus lower LED strip overhead stowage compartment and lighting for corner shelf
E3b
Earth and plus
E4
E5
Earth and plus LED strip for bar
F1
Earth and plus outer tent light, LED lighting for step
F2
Earth and plus awning rail lighting
Earth and plus downlighters
F3
Earth and plus
F4
S46
Input 230 V phase and neutral
S35
Input 230 V boiler
Output 230 V floor heating
S34
PE1
Protective earth input 230 V
PE2
Protective earth output boiler
PE3
Protective earth output floor heating
PE4
Protective earth connector for connection to earth power supply low voltage
PE5
Connector earth power supply/devices for connection to protective earth
Control panel in bedrooms, keys 1,7,8,9,C
Control panel in bedroom keys 1,7,8,9,C
Control panel external lighting
Main panel
7x Ci-Bus
67
7. Installation of electrical devices
Safeguarded
Designation
10 A fuse
10 A fuse
A
10 A fuse
10 A fuse
10 A fuse
10 A fuse
10 A fuse
10 A fuse
B
10 A fuse
10 A fuse
10 A fuse
5 A fuse
5 A fuse
C
5 A fuse
5 A fuse
5 A fuse
5 A fuse
5 A fuse
D
5 A fuse
5 A fuse
5 A fuse
7.5 A fuse
7.5 A fuse
7.5 A fuse
7.5 A fuse
E
7.5 A fuse
7.5 A fuse
7.5 A fuse
7.5 A fuse
7.5 A fuse
7.5 A fuse
F
7.5 A fuse
7.5 A fuse