Maintenance And Care; Maintenance; Mechanical; Repairs - probst SDH-H-15 Operating Instructions Manual

Hydraulic manhole cover lifter
Hide thumbs Also See for SDH-H-15:
Table of Contents

Advertisement

Maintenance and care

5
Maintenance and care
5.1

Maintenance

To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
All operations may only be made in closed state of the device!
5.1.1

Mechanical

SERVICE INTERVAL
First inspection after
25 operating hours
All 50 operating hours
Minimum 1x per year
(at rough conditions shorten the
interval)
5.2

Repairs

Only persons with the appropriate knowledge and ability are allowed to repair the device.
Before the device is used again, it has to be checked by an expert.
5480.0002
Maintenance work
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
Tighten all screws and connections (take care that the tightening torques according to
the property class of the screws are observed).
Check all existing safety elements (such as linchpins) for perfect function and replace
defective safety elements.  1)
Check all joints, bolts, guidance's and gears for correct function, if necessary adjust or
replace it.
Check all grippers (if available) for signs of wear.
Grease all slidings (if available) when the device is in opened position with a spatula.
Grease all grease nipples (if available) with a grease gun.
Check of all the suspension parts, bolts and straps. Check for corrosion and safety by an
expert.
1)
V5
13 / 15
GB