Repair; Disassemble The Fluid Section - Graco ChemSafe 515 PT Instructions-Parts List Manual

Air-operated diaphragm pump
Hide thumbs Also See for ChemSafe 515 PT:
Table of Contents

Advertisement

Repair

Repair
Repair
Repair
NOTE:
NOTE: Before repairing the pump, follow the
NOTE:
Pressure Relief Procedure, page
Disassemble the
the Fluid
Disassemble
Disassemble
the
1. Carefully remove all cap plugs (37). Turn the
pump upside-down.
2. Use a 10 mm socket to remove the base plates
(12) and the inlet manifold (10).
3. Remove the o-ring seals (17), d-rings (21), and
check balls (22) from inlet side of each fluid cover
(6).
4. Inspect the inlet ball retainers (20). If necessary
to replace, use a hook to remove without
scratching the inner bore.
5. Turn over the pump and use a 10 mm socket to
remove the manifold retainer (11) and the outlet
manifold (8).
18
Tel: 866-777-6060
Fax: 866-777-6383
14.
Fluid Section
Section
Fluid
Section
Springer Pumps, LLC
6. Inspect both manifolds' (8 & 10) wearable seats
(35 & 36), and replace if worn or damaged.
NOTE: Use a small hammer and PVC tool (44)
NOTE:
NOTE:
to tap new wearable seats (35 & 36) into the
manifolds (8 & 10).
7. Remove the o-ring seal (17) from the outlet side
of each fluid cover (6).
8. Without scratching the inner bore, use a hook to
remove the two outlet ball retainers (20).
Website: www.springerpumps.com
334794F
Int'l: +001 267 404 2910

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chemsafe 515 uh

Table of Contents