Jumper Settings - Infineon TLE987 Series User Manual

Hide thumbs Also See for TLE987 Series:
Table of Contents

Advertisement

TLE987x EvalBoard

4 Jumper settings

4
Jumper settings
Figure 9
Jumpers
JP2
JP3
JP5
VDDEXT_LED
ILoadVS
ILoadVSD
SINN/P
Debugger Jumper
User Manual
ILoadVS
Set this jumper to connect RESET button to RESET pin.
Open it to disconnect RESET button from RESET pin.
Set this jumper to terminate TLE987x in daughter board as LIN master.
Open it to terminate TLE987x in daughter board as LIN slave.
Set this jumper to connect MON button to MON pin.
Open it to disconnect MON button from MON pin.
Set this jumper to enable LED operation at VDDEXT.
This jumper is closed by default.
If this jumper is left open the device is not supplied.
Target is to measure the current flowing into the TLE987x device.
This jumper is closed by default.
If this jumper is left open the charge-pump is not supplied.
Target is to measure the charge-pump current consumption.
Set to use TMR sensor interface.
Open debugger jumper to use off-board SWD debugger.
JP3
VDDEXT_LED
POTI
ILoadVSD
SUPPLY
SINN
JP5
LEDs & PINs
10
POTI
SIGNAL
P0.4
P1.2
SINP
JP2
Debugger
Jumper
2020-07-30
v1.0

Advertisement

Table of Contents
loading

Table of Contents