HOW TO GET INSIDE YOUR CATGENIE
To take apart your CatGenie, move the CatGenie away from the
wall. Keep the DrainHose in the toilet or drainpipe. Take off the
Hopper Cover. Remove the Processing Unit and place it upright on
a towel on the floor. Lean the Unit securely against the wall. Unclip
WARNING: Unless a Manual instructs otherwise, always unplug the Genie power cord before you work on your CatGenie.
Be sure to plug it back in you're finished. Removing the Processing Unit also interrupts power.
HOW TO REPLACE PARTS.
Spare Parts Kit is under the Base.
Keep it there until needed.
RED WASHER:
Attaches to the bottom of the
Hopper and connects to the
WATER SENSOR:
DrainHose. The Red Washer is a
If the Sensor Tip gets
Critical piece. It prevents waste-
scratched or damaged
water leaks. It's important that it
it won't work. Replace
is not squeezed or defective.
with the extra Sensor
Make sure that it is securely in
in the Spare Parts Kit
place on the Hopper. Keep it
under the Base.
lubricated with baby oil
or liquid
www.catGenie.com
If working on the Processing Unit, first unplug the power cord.
Spares available under Genie Base. Or from us.
3/4" T-ADAPTER WASHER
for LAUNDRY SETUP:
Check if Lock-Nut side of
the T-Adapter has its Black
Washer. If missing, purchase
at a hardware store.
Or call us toll free at
1-888-735-3927.
soap.
if you need to replace a part.
the GenieHand . Push Arm and Clip back into the opening. To remove
Brim, push on Black Button for leverage as you pull up the Brim back.
Put aside. Hopper is accessible for removal if necessary. To get to the
Base, remove the Bowl of Granules. Set aside where cats can't use.
ORANGE NIPLET:
Located at the bottom of the Processing Unit. The Niplet
prevents the SaniSolution from drying out and clogging the
white dispenser Nozzle to which it is attached. To check if
it's OK, unplug CatGenie. Carefully lift the Unit from its slot.
To clean Niplet, squeeze out clumped Solution. Then wash
with warm water. If missing, get one from Spare Parts.
Put Niplet onto the white Nozzle. Clean Unit slot on the
Brim. Wipe bottom of Unit with a soft cloth. Carefully and
securely put Unit back into its slot. Plug in the CatGenie.
SPACER DISCS:
If you have excessive loss of Granules under
the Brim, Spacer Discs are provided in the Spare Parts
Kit under the Base. Follow directions.
Add just one Disc to the Knob in the center of
the Base, on which the Bowl rotates. Put the CatGenie
back together. Before adding the Processing Unit, spin
the Bowl to check that Bowl moves easily. Run a
Cycle to test that all works.