Vimar 02952 Installer Manual page 8

Knx touch thermostat.
Table of Contents

Advertisement

Thermostat
Communication objects and ETS parameters
Continued
No.
ETS name
Function
18
Status
A: Summer - Winter - status
19
Enable
A: Summer - Winter - control
A: OFF communication - bus
20
Thermostat Off
- control
21
Dewpoint
A: Thermostat - control
22
NOT USED
23
Current Setpoint
A: Setpoint - status
24
Setpoint Shift
A: Setpoint - status, control
25
Winter Comfort
A: Setpoint - status, control
26
Winter Standby
A: Setpoint - status, control
27
Winter Energy Saving
A: Setpoint - status, control
28
Winter Protected
A: Setpoint - status, control
29
Summer Comfort
A: Setpoint - status, control
30
Summer Standby
A: Setpoint - status, control
31
Summer Energy Saving A: Setpoint - status, control
32
Summer Protected
A: Setpoint - status, control
33
NOT USED
Thermostat A: Valves
34
Cooling/Heating Valve
A: Valve
34
Cooling Valve
A: Valve
35
Heating Valve
A: Valve
34
Cooling/Heating Valve
A: Valve
34
Cooling Valve
A: Valve
Continued
8
Description
To read the seasonal mode set on the thermostat (0 =
Summer, 1 = Winter)
To set the seasonal mode on the thermostat (1 = Win-
ter, 0 = Summer). If it is NOT associated with a group
then thermostat A will function in Neutral Zone mode.
This function is useful in the event of faults on the heat-
ing system to disable the valves with a 1 bit.
If a 1 bit is sent to this object, the thermostat will show
the specific icon on the display, turn OFF and stop the
air conditioner (this works only in air conditioning mode
and serves for example to avoid condensation on the
floor) - Note: The thermostat requires a cyclical send to
this object, with a time that can be set in the parameter
"Dewpoint Supervision Time"
To read the temperature setpoint set on the thermostat.
If you want Well-contact Suite to know the setpoint cur-
rently set on the thermostats, this object must be linked
to a group
To read and control a temperature shift with respect to
the current setpoint (setpoint set by ETS on the thermo-
stat for the various operating modes CMF, STBY, etc.).
The temperature shift permitted is limited to the range
set by the parameter: Guest Control Permitted.
If parameter Guest Control Permitted is set to Off the
"Setpoint Shift" object does not shift the active setpoint.
To read and set the Winter Comfort setpoint.
To read and set the Winter Standby setpoint
To read and set the Winter Economy setpoint
To read and set the Winter Antifreeze setpoint
To read and set the Summer Comfort setpoint
To read and set the Summer Standby setpoint
To read and set the Summer Economy setpoint
To read and set the Summer Too Hot setpoint (power-off
of climate control if the window is opened, for instance)
If the "Valve" parameter is set for 2-pipe systems for
valve management: to be used to control the head of a
radiating system or the On/Off valve of a fan coil
If the "Valve" parameter is set for 4-pipe systems for
valve management in Summer: to be used to control
the head of a radiating system or the On/Off valve of a
fan coil
If the "Valve" parameter is set for 4-pipe systems for
valve management in Winter: to be used to control the
head of a radiating system or the On/Off valve of a fan
coil
If the "Valve" parameter is set for 2-pipe proportional
systems for proportional valve management: to be
used to control the head of a radiating system or for the
proportional valve of a fan coil
If the "Valve" parameter is set for 4-pipe proportional
systems for Summer valve management: to be used to
control the head of a radiating system or for the propor-
tional valve of a fan coil
C = Communication; R = Read; W = Write; T = Transmission; U = Enable update
Flag 1
Type
Priority
C R W T U
I
1 bit
C
R
-
T
-
- Low
1 bit
C
- W - U
- Low
1 bit
C
- W - U
- Low
1 bit
C
- W - U
- Low
2 byte
C
R
-
T
-
- Low
2 byte
C
R W T
-
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
1 bit
C
R
-
T
-
- Low
1 bit
C
R
-
T
-
- Low
1 bit
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low