Download Print this page
Vimar 02973 Manual

Vimar 02973 Manual

Smart home view wireless, connected dial thermostat

Advertisement

Quick Links

SMART HOME VIEW WIRELESS
02973 - Connected dial thermostat
TWO OPERATING MODES (ALTERNATIVE)
Stand alone •
Download the View Wireless
App from the stores onto the tablet/smartphone you
will be using for configuration.
When the device is powered for the first configuration, we recommend you search for any
new firmware and perform the update.
Depending on the mode you select, you will need:
Stand alone
Nothing else
Amazon Alexa, Google Assistant, Siri and Homekit voice
assistants for possible voice operation
Create your Installer account on MyVimar (on-line).
STAND ALONE CONFIGURATION
1. Wire all the thermostats.
2. Start the View Wireless App and log in with the credentials you just created.
3. Create the system and the environments.
4. Associate all the thermostats with the environments.
To associate the thermostat:
• Select "Add" (
), choose the environment to place it and give it a name
• Select
; activate the Bluetooth connection on your tablet/smartphone and approach the
thermostat
• Press
for 5 s; the ring flashes blue and association is complete.
5. For each thermostat, set the functions and parameters.
6. Go to the "Temperature control" menu and for each thermostat set the time schedules, the
setpoints for the operating modes and the current time.
CONFIGURATION IN
1. Wire all the devices in the system (2-way switches, relays, thermostats, gateway, etc.).
2. Start the View Wireless App and log in with the credentials you just created.
3. Create the system and the environments.
4. Associate all the devices with the environments, except for the gateway (which should be
associated last).
To associate the thermostat:
• Select "Add" (
), choose the environment to place it and give it a name
• Select
; activate the Bluetooth connection on your tablet/smartphone and approach
the thermostat
• Press
for 5 s; the ring flashes blue and association is complete.
5. For every device, set the function, the parameters and any accessory devices (wired or radio
control and related function).
6. Transfer the configuration of the devices to the gateway and connect it to the Wi-Fi network.
7. Transfer the system to the Administrator user (who must have created his/her profile on
MyVimar).
For full details, see the View Wireless App manual that can be downloaded from the www.
vimar.com website.
RESETTING THE THERMOSTAT
The reset restores the factory settings. Within the first 5 minutes of powering, press
s; during these 30 s the ring flashes blue and then emits 2 white flashes to confirm the operation.
THERMOSTAT DATE/TIME SETTING
In the event of a mains voltage outage, if the thermostat is configured in Stand alone and the
"ON Mode"-"Automatic" is set, the date and time can be inserted directly on the device without
using the App.
1. Press
; you have entered the "Time entry" phase; during this phase, keys
are not operational.
2. Turn the ring and display the number representing the desired day of the week (1=Monday,
2=Tuesday, 3=Wednesday and so on).
3. Confirm by pressing
; now proceed and set the time.
4. Turn the ring and display the number representing the hours (00, 01, 02 and so on all the way
to 23).
5. Confirm by pressing
; now proceed and set the minutes.
6. Turn the ring and display the number representing the minutes (00, 01, 02 and so on all the
way to 59).
7. Confirm by pressing
; the thermostat returns to the state it was in before the blackout and
the display and part 2 of the ring stop flashing.
02973 03 2207
Gateway
art. 20597-19597-16497-14597
View App
for management via smartphone/tablet
A
B
1
• Short press = degrees Celsius/Fahrenheit selection
• Long press (5 s) = the thermostat enters the configuration phase (bt)
• Prolonged press (30 s) within the first 5 min of powering = device reset (rst)
• 1st press = current brightness display
• Subsequent presses = cyclic display of available brightness values L-3 (high), L-2
(medium), L-1 (low) and L-0 (off).
• bt = devices in Bluetooth configuration
• off = thermostat off; on = thermostat on
• °C = degrees Celsius; °F = degrees Fahrenheit
A
• L-0, L-1, L-2, L-3 = brightness in standby (from the lowest to the highest)
• H = heating; C = air conditioning
• opn = open window (associated with the thermostat via magnetic contact art.
03980)
B
Dial
C
Lightable ring
• Power on and off.
Upon power on or off, the thermostat starts in the last operating mode associated
with it set via the View App.
• Heating or air conditioning mode selection.
All flashing blue = thermostat in configuration mode
All lit amber* = thermostat in heating mode and relay active
All lit blue** = thermostat in air conditioning mode and relay active
• Lit amber * = thermostat in heating mode and relay not active
• Lit blue ** = thermostat air conditioning mode and relay not active
1
In standby, the brightness is set during configuration; otherwise, the value is the
maximum one.
• Flashing red = the thermostat, in automatic mode, has lost the hourly value and
for 30
2
When it receives the hourly value from the gateway again, the thermostat returns
to automatic mode and the flashing ends.
* Amber with automatic colour or of the selected colour.
** Blue with automatic colour or of the selected colour.
,
and
N.B. During the selection phases, the display and part 2 of the ring flash and key
If no selection is made within 2 minutes, the thermostat quits the procedure.
To change the time without a blackout press
1 to 7 above.
Display brightness and RGB LED in standby setting
Display
Ring signalling
has therefore switched to manual mode.
for 5 s and perform the procedure from point
36063 Marostica VI - Italy
C
2
flashes red.
Viale Vicenza 14
www.vimar.com

Advertisement

loading

Summary of Contents for Vimar 02973

  • Page 1 SMART HOME VIEW WIRELESS 02973 - Connected dial thermostat TWO OPERATING MODES (ALTERNATIVE) Stand alone • Download the View Wireless App from the stores onto the tablet/smartphone you will be using for configuration. When the device is powered for the first configuration, we recommend you search for any new firmware and perform the update.
  • Page 2 EN 60730-2-7, EN 60730-2-9, EN 301 489-17, EN 300 328, EN 62479, EN 63000 standards. • Relay output with voltage-free contact: 5(2) A 240 V~ Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text • Input for external sensor (art. 02965.1-20432-19432-14432) with the following functions: XX...
  • Page 3 CONNECTIONS: Circulation pumps, burners, solenoid valves and temperature probe 03980 100-240 50/60Hz -T40 6 mm 100-240V~ 5(2)A 50/60Hz 1.B.U -T40 6 mm 20432-19432-14432 02973 02965.1 Viale Vicenza 14 36063 Marostica VI - Italy www.vimar.com 02973 03 2207...

This manual is also suitable for:

2059719597164971459702973.b