Vimar 02952 Installer Manual page 11

Knx touch thermostat.
Table of Contents

Advertisement

Thermostat
Communication objects and ETS parameters
Continued
No.
ETS name
Function
72
Winter Comfort
B: Setpoint - status, control
73
Winter Standby
B: Setpoint - status, control
74
Winter Energy Saving
B: Setpoint - status, control
75
Winter Protected
B: Setpoint - status, control
76
Summer Comfort
B: Setpoint - status, control
77
Summer Standby
B: Setpoint - status, control
78
Summer Energy Saving B: Setpoint - status, control
79
Summer Protected
B: Setpoint - status, control
80
NOT USED
Thermostat B: Valves
81
Cooling/Heating Valve
B: Valve
81
Cooling Valve
B: Valve
82
Heating Valve
B: Valve
81
Cooling/Heating Valve
B: Valve
81
Cooling Valve
B: Valve
82
Heating Valve
B: Valve
Thermostat B: Second Stage
83
Cooling Valve
B: 2
83
Cooling Valve
B: 2
84
Heating Valve
B: 2
84
Heating Valve
B: 2
Thermostat B: Fan
85
Proportional (0- 100%) B: Fan Inputs
86
NOT USED
87
V1 speed
B: Fan Inputs
Continued
Description
To read and set the Winter Comfort setpoint.
To read and set the Winter Standby setpoint
To read and set the Winter Economy setpoint
To read and set the Winter Antifreeze setpoint
To read and set the Summer Comfort setpoint
To read and set the Summer Standby setpoint
To read and set the Summer Economy setpoint
To read and set the Summer Too Hot setpoint (power-off
of climate control if the window is opened, for instance)
If the "Valve" parameter is set for 2-pipe systems for
valve management: to be used to control the head of a
radiating system or the On/Off valve of a fan coil
If the "Valve" parameter is set for 4-pipe systems for
valve management in Summer: to be used to control
the head of a radiating system or the On/Off valve of a
fan coil
If the "Valve" parameter is set for 4-pipe systems for
valve management in Winter: to be used to control the
head of a radiating system or the On/Off valve of a fan
coil
If the "Valve" parameter is set for 2-pipe proportional
systems for proportional valve management: to be
used to control the head of a radiating system or for the
proportional valve of a fan coil
If the "Valve" parameter is set for 4-pipe proportional
systems for Summer valve management: to be used to
control the head of a radiating system or for the propor-
tional valve of a fan coil
If the "Valve" parameter is set for 4-pipe proportional
systems for Winter valve management: to be used to
control the head of a radiating system or for the propor-
tional valve of a fan coil
If second cooling stage is enabled to be used for the
Cooling Stage
nd
boost function (cooling) for on/off valve control
If second cooling stage is enabled to be used for the
Cooling Stage
nd
boost function (cooling) for proportional valve control
If second heating stage is enabled to be used for the
Heating Stage
nd
boost function (heating) for on/off valve control
If second heating stage is enabled to be used for the
Heating Stage
nd
boost function (heating) for proportional valve control
Used to set a proportional speed for the fan coil fan (if
the selected fan is proportional or 8-bit with 3 speeds)
via a supervisor (e.g., touch screen)
Used to force activation of fan coil speed V1 (if the
selected fan has 3 speeds)
C = Communication; R = Read; W = Write; T = Transmission; U = Enable update
Flag 1
Type
Priority
C R W T U
I
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
2 byte
C
R W T U
- Low
1 bit
C
R
-
T
-
- Low
1 bit
C
R
-
T
-
- Low
1 bit
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low
1 bit
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low
1 bit
C
R
-
T
-
- Low
1 byte
C
R
-
T
-
- Low
1 byte
C
- W -
U
- Low
1 bit
C
- W -
U
- Low
11

Advertisement

Table of Contents
loading

Table of Contents