8 | English
(d)
Zoom level display (see "Setting the zoom level",
page 11)
(e)
Bluetooth® display switched on (see "Data transfer
via Bluetooth®", page 14)
(f)
Battery charge indicator
(g)
Function indicator/measured value for relative hu-
midity
(h)
Function indicator/measured value for ambient tem-
perature
(i)
Function indicator/result for dew point temperature
(j)
Minimum/maximum measured value for surface tem-
perature during a measurement
(k)
Result scale
(l)
Menu symbol
(m) Surface temperature alarm display (see "Surface tem-
perature alarm", page 13)
Technical Data
Thermo detector
Article number
Working range
Measuring range
– Surface temperature
– Contact temperature
– Ambient temperature
– Relative humidity
A)
Measuring accuracy
B)
Surface temperature
–40 to –20.1 °C
–20 to –0.1 °C
0 to +100 °C
+100 °C to +400 °C
> +400 °C
Ambient temperature
C)
Relative humidity
< 20 %
20 to 60 %
60 to 90 %
Optics (measuring distance:measured surface ratio)
Laser class
Laser type
Divergence (full angle)
Max. altitude
Pollution degree according to IEC 61010-1
Relative humidity max.
Non-rechargeable batteries (alkaline manganese)
1 609 92A 62P | (14.10.2020)
(n)
Measured value
(o)
Current mode
(p)
Mark for measured value or result (depending on se-
lected mode)
(q)
Gallery symbol
(r)
Function indicator/measured value for average tem-
perature
(s)
Function indicator/measured value for contact tem-
perature
Emissivity/reflected temperature indicator
(t)
(u)
Set external temperature
(thermal bridge mode)
(v)
Display of f
Rsi
(thermal bridge mode)
GIS 1000 C
3 601 K83 3..
–40 to +1000 °C
–40 to +1000 °C
–10 to +50 °C
D)E)
635 nm, < 1 mW
4 × 1.5 V LR6 (AA)
(with battery adapter)
value with tolerance
GIS 1000 C
3 601 K83 371
0.1–5 m
0.1–5 m
–40 to +1000 °C
–40 to +1000 °C
–10 to +50 °C
0 to 100 %
0 to 100 %
±2.5 °C
±1.5 °C
±1 °C
±1 %
±2 %
±1 °C
±3 %
±2 %
±3 %
50 : 1
2
635 nm, < 1 mW
< 1.5 mrad
< 1.5 mrad
2000 m
2000 m
F)
2
90 %
4 × 1.5 V LR6 (AA)
Bosch Power Tools
±2.5 °C
±1.5 °C
±1 °C
±1 %
±2 %
±1 °C
±3 %
±2 %
±3 %
50 : 1