Param. Description
P275
DO1
Output
(*)
Function
P276
DO2
Output
(*)
Function
P277
DO3
Output
(*)
Function
ATTENTION!
When the accessory is connected, the four
digital inputs of the product (DI1 to DI4) lose
their functionalities.
I/O Expansion Module and
Incremental Encoder Input
Adjustable
Range
0 = Not Used
1 = F* ≥ Fx
2 = F ≥ Fx
3 = F ≤ Fx
4 = F = F*
5 = Not Used
6 = Is>Ix
7 = Is < Ix
8 and 9 = Not Used
10 = Remote
11 = Run
12 = Ready
13 = Without Fault
14 = Without F070
15 = Not Used
16 = Without F021/F022
17 = Not Used
18 = Without F072
19 = 4-20 mA OK
20 = Not Used
21 = Forward
22 to 23 = Not Used
24 = Ride-Through
25 = Pre-charge OK
26 = With Fault
27 = Not Used
28 = SoftPLC
29 to 34 = Not Used
35= Without Alarm
36 = Without Fault /Alarm
37 = Function 1 Application
38 = Function 2 Application
39 = Function 3 Application
40 = Function 4 Application
41 = Function 5 Application
42 = Function 6 Application
43 = Function 7 Application
44 = Function 8 Application
See options of P275
See options of P275
Factory
Prop.
Setting
13 =
cfg
Without
Fault
0 = Not
cfg
Used
0 = Not
cfg
Used
CFW100 | 9