I/o expansion module and incremental encoder input
Table of Contents

Advertisement

Available languages

Available languages

I/O Expansion Module and
Incremental Encoder Input
Param. Description
Input DI1
P263
Function
Input DI2
P264
Function
Input DI3
P265
Function
8 | CFW100
Adjustable
Range
0 = Not Used
1 = Run/Stop
2 = General Enable
3 = Quick Stop
4 = Forward
5 = Reverse
6 = ON
7 = OFF
8 = Direction of Rotation
9 = LOC/REM
10 = JOG
11 = Accelerate P.E.
12 = Decelerate P.E.
13 = Multispeed
14 = 2
Ramp
nd
15 to 17 = Not Used
18 = Without Ext. Alarm
19 = Without Ext. Fault
20 = Reset
21 to 23 = Not Used
24 = Disab. Flying Start
25 = Regul. DC Link
26 = Lock Prog.
27 to 31 = Not Used
32 = Multispeed 2
33 = Acel. P.E. 2
34 = Decel. P.E. 2
35 = Forward Run 2
36 = Reverse Run 2
37 = ON/Acel. P.E.
38 = Decel. P.E./OFF
39 = Stop
40 = Safety Switch
41 = Function 1 Application
42 = Function 2 Application
43 = Function 3 Application
44 = Function 4 Application
45 = Function 5 Application
46 = Function 6 Application
47 = Function 7 Application
48 = Function 8 Application
See options of P263
See options of P263
Factory
Setting
1 = Run/
Stop
Ramp
nd
Ramp
nd
Ramp
nd
Ramp
nd
Ramp
nd
8 =
Direction
Rotation
0 = Not
Used
Prop.
cfg
cfg
of
cfg

Advertisement

Table of Contents
loading

Table of Contents