Analog Input Data Format; Configure Analog Input Module; Configure Analog Modules With Rsnetworx - Rockwell Automation Allen-Bradley 1790D-N4CO Manual

Compactblock ldx i/o analog modules
Table of Contents

Advertisement

Analog Input Data Format

Configure Analog Input
Module
Configure Analog Modules
with RSNetWorx
Chapter 3
Table 18 - Word/Bit Descriptions (Continued)
Word
Decimal Bit
Bits 00...11
Read Word 1
Bits 12...15
Bits 00...11
Read Word 2
Bits 12...15
Bits 00...11
Read Word 3
Bits 12...15
Bits 00...03
Read Word 4
Bits 04...15
Read Word 5
Bits 00...15
Read Word 6
Bits 00...15
Analog input data is presented as raw or proportional. The full 12-bit resolution
is used over the entire span of the input full scale range, as shown in
Table 19 - Bit Resolution
Input Full Scale
Module
Range
1790D-TN4V0
0
10V DC
...
4
20 mA
...
1790D-N4C0
1790D-TN4C0
0
20 mA
...
RSNetWorx for DeviceNet allows you to identify the network and configure
the I/O modules with easy-to-use Electronic Data Sheets (EDS). Point to the
field and click your selection.
To download EDS files for use in configuration, go to rok.auto/pcdc.
EDS files for blocks with matching catalog numbers (for D-shell and
removable terminal block versions) are the same. The website, or in
RSNetWorx for DeviceNet, there may be only one catalog number that is listed
for both versions.
When using third-party configuration software, load the EDS files into the
software and follow the vendor's instructions.
To configure analog modules, follow these steps:
1. Open RSNetWorx for DeviceNet.
2. Add an analog input module (for example, 1790D-N4C0) to the network,
as shown in
Figure
Rockwell Automation Publication 1790-UM001B-EN-P - April 2021
Module Data, Status, and Channel Configuration for Analog Input Modules
Description
Channel 1 input data
Not used: Set to 0
Channel 2 input data
Not used: Set to 0
Channel 3 input data
Not used: Set to 0
Status bits for individual channels — Bit 00 corresponds to input channel 0, bit 01
corresponds to input channel 1 and so on. When set (1) indicates:
No field power
Open wire — 4...20 mA current input only
Under range — 4...20 mA current input only
Recoverable module fault (whole channel to be set)
Unrecoverable module fault (whole channel to be set)
Not used: Set to 0
First discrete Input expansion data
Second discrete Input expansion data
HEX Data Range
Decimal Data Range
0000
0FFF
0
...
...
0000
0FFF
0
...
...
0000
0FFF
0
...
...
14.
Table
19.
Input Resolution
4095
2.44 mV
4095
3.90A
4095
4.88A
29