General Settings

Configures the panel type: General entrance panel or block panel.

3.2.1 General Entrance Panel

DEVICE NO.: General entrance panel number, between 1 and 9000.
TYPE: G.E.PANEL. The panel can communicate with all devices (monitors or concierges) of
the installation.
LANGUAGE: select the desired language in the dropdown options. Default option ENGLISH.
Refresh the webpage after change the language.
INFORMATION: 9901 CONCIERGE, Prompt information to be displayed on the panel, between
9901-9998, default option 9901. It is possible to modify the number according to the main
concierge that each panel will call.
PANEL VOLUME: Select the desired value between 1 and 5. Default option 4).
The conversation volume is common for uplink and downlink.
DOOR OPEN VOICE SYNTH: The door open voice synth. can be enabled or disabled. The
default is enabled.
VIDEO RESOLUTION: In order to fit the different types of monitor. The default value 640×480
is to be used the most usually.
SIP DIVERT MODE:
PARALLEL CALL: When the panel calls the resident, the monitor and the call divert APP ring
at the same time. Once one terminal answers the call the other one stops ringing.
SEQUENTIAL CALL: When the panel calls the resident, the monitor will ring about 30s if no
answer, the call divert APP will start to ring
This feature may not be available in this version. Will always works in PARALLEL CALL mode.
DATE FORMAT: Date format.
DATE: Setting the date of panel.
TIME: Setting the time of panel.
TIME ZONE: Setting the time zone of panel.
DST: Daylight saving time option. Will increase the time by 1h when selected. The daylight
saving option is not automatic.
If the project has no management software nor internet connection the installer can set date,
time and time zone manually.
If the project has management software, the date and time of panel will synchronize
automatically with the management software. If the panel has access to internet, the date and
time of the panel will synchronize with internet time server.
Date and time can't be saved after power loss, but the time zone and date/time format can be saved.