2-4-3. Operation Check of Reset Switch
Procedure
1. Turn off the power of this unit.
2. Turn on the power of this unit while pushing the reset switch (S901/SW-1654 board) in the rear
portion of this unit using the tool having a long and thin tip.
3. The NETWORK indicator of this unit is lit in amber for a while, which is different from the normal
power ON state.
After a period of time, the resetting is started and each indicator repeats blinking in the following
sequence.
NETWORK: Lights up in green. → Lights up in yellow. → OFF → Lights up in green. → Lights
up in amber → OFF
POWER:
Lights up in green. → OFF → Lights up in green. → OFF → Lights up in green. → OFF
Check that when the resetting is completed, each indicator is lit as follows and the image is output on
the SDI monitor.
NETWORK: stays lit in green.
POWER:
stays lit in green.
End
1. Turn off the power of each device and disconnect the connections.
SRG-300SE/301SE
2-21 (E)