To command the output 3, enter any one of the User Codes in Group 3 into the keypad and validate via
c)
#
the
key
9270 #
------------ Output 3 starts (or stops)
22898 #
---------- Output 3 starts (or stops)
d)
The Personal Master Code is also a
Super User Code
operate all the 3 outputs. To command output 1, 2 or 3, enter the Personal Master Code and validate via
#
the
key and the corresponding output number.
3289 #1
---------- Output 1 activates for 1 second
3289 #2
---------- Output 2 starts (or stops)
3289 #3
---------- Output 3 starts (or stops)
The
do not need to program. The keypad determines it automatically by increasing the
e)
Duress Codes
first digit of the
User Codes Two units
. All the User Codes in Group 1 have Duress Code Function.
For example:
User Codes of Group 1
8321
11223
33221
To command the Duress Function, enter the Duress Code(s).
0321 #
----------- Duress output activates (output switches to ground) & Output 1 activates for 1
second
31223 #
---------- Duress output activates (output switches to ground) & Output 1 activates for 1
second
53221 #
---------- Duress output activates (output switches to ground) & Output 1 activates for 1
second
NOTE:
i) The Duress Code(s) has double actions. It activates the Duress Output and at the same time activates
the Output 1 as like the User Codes of Group 1. The Duress Code(s) can always activates or
deactivates (in Start / Stop mode) Output 1, but cannot deactivate (reset) the Duress Output. ONLY the
User Codes of Group 1 can deactivate (reset) the Duress Output.
ii) All alarms will be stopped, including the door forced-open-alarm and the door open-too-long alarm,
when Duress function is in operation.
f)
The
Accelerated Code
is the
First Two Digits
3 has been programmed in Start / Stop mode with Accelerated Code, it is possible to
corresponding Output 1, 2 or 3 with only the First Two Digits of the User Code(s). Deactivating of the
corresponding Output 1, 2 or 3 always requires the composition of the Complete User Code(s).
In this example, Output 3 has been programmed in Start / Stop Mode with Accelerated Code.
The Complete Code of 1st User Code of Group 3:
2nd User Code of Group 3:
92 #
---------------- Output 3 starts
9270 #
------------ Output 3 stops
22 #
---------------- Output 3 starts
22898 #
---------- Output 3 stops
. It allows the owner to use Only One Code to
The Corresponding Duress Codes
0321
31223
53221
of the User code(s). If the User Code(s) of Group 1, 2 or
activate
9270
The Accelerated Code is:
92
22898
The Accelerated Code is:
22
11
Try to put some random false codes to the keypad to test its
g)
each unsuccessful code entry. The keypad locks itself during 15 minutes after 10 successive false codes
are entered. Normal operation will be resumed after 15 minutes expired, or, it can be reset with the Master
Code during the locking period.
3289 #
---------------- Locking is reset and keypad resumes normal operation
h)
In this example, the keypad has been programmed with
door that is equipped with
alarm will activate instantly for 60 seconds. The alarm can be stopped by any of the User Codes in Group
1 before the end of the alarm time.
8321 #
---------------- Alarm stops
NOTE:
The testing may not be feasible if the door is locked. It is necessary to un-lock the door with the
mechanical key before testing.
The
i)
Door Open-Too-Long Alarm
or the
Egress Button
more than 60 seconds (the programmed time). The alarm starts. Close the door, the alarm stops
automatically. This feature reminds the owner to close the door in case it is stuck.
The keypad incorporates
j)
C) RE-PROGRAM THE KEYPAD WITH NEW DATA
It is possible to change the current data at anytime, such as change the User Codes, Door Open timing, etc.
1)
Make the system in
Programming Mode
3289 *
----------------- The keypad is in Programming Mode
2)
After the system is in Programming Mode, you can enter the appropriate "Access Keys" number and put in
the new data in the location. Please see the programming "Summary Chart" for details. You can re-program
any individual item in the Summary Chart.
It is necessary to exit the programming mode and save the new data after programming via the
3)
*
---------------------------- All the new data are saved and the keypad is back to normal operation mode
the
Safety
Door Forced-Open-Alarm
Door Sensing Switch
, without the use of
has been enabled in programming. Try to command Output 1 with
. Open the door that is equipped with
Door Sensing Switch
. To activate the door chime, just simply press the
Door Chime
first. Enter your Personal Master Code and validate via
&
ready to receive new data
12
. The keypad generates 5 beeps for
enabled. Try to open the
Code 1
or the
Egress Button
. The
Code 1
, and leave it open for
key.
BELL
*
key.
*
key