SET THE SYSTEM TO SINGLE USER MODE
You are required to decide the keypad for Single User or Multi-User Mode in operation. The system can be set for
with the command code "
Single User Mode
8900
mode.
* 8900 # --------
MASTER CODE
Single User Mode

SET THE SYSTEM TO MULTI-USER MODE

he system can be set for
Multi User Mode
with the command code "
T
system is refreshed for other mode.
* 8901 #
MASTER CODE
Multi-User Mode
REFRESH THE SYSTEM
-- CHANGE OF OPERATION MODE
A system was set to
Single User Mode.
It is possible to change it to
the system with the above operation command codes.
A refreshed keypad will reset itself as a fresh unit with the Default Values.
previously are cleared except the Master Code.
IMPORTANT NOTES:
1)
Make sure all the
User Codes
and
Master Code
User Mode operation. Otherwise, code entry will not be successful.
2)
It is necessary to change the Master Code to 4 digits first (if it was more than 4 digits in Multi Users Mode)
before refreshing from Multi User Mode to Single User Mode.
The system takes approximate 2 to 3 seconds to refresh itself for new operation mode after the refresh code is
3)
entered. DO NOT enter any code during the system is being refreshed until the 2 confirmation beeps are heard.
PROGRAM AND USE THE KEYPAD -- OPERATION
Once the operation mode is selected - Single User or Multi Users, all the three outputs will operate with that mode.
A) SINGLE USER MODE OPERATION -- An Example
1) Re uirement
q
-- Set the following data into the system:
a) Single User Mode Operation
b) Change the factory-set Master Code 0000 to a Personal Master Code 3289
c) Set User Code 1 in 8321
d) Set User Code 2 in 6854
e ) Set User Code 3 in 9270
f ) Set Output 1 in Momentary Mode, 1 second
g) Set Output 2 in Start / Stop Mode without accelerated code
h) Set Output 3 in Start / Stop Mode with accelerated code
i ) Set the keypad to lock itself during 15 minutes after 10 successive false codes
j ) Set the keypad with door Forced-Open-Alarm enabled
k ) Set the allowable time for door left open for 60 seconds before triggering of the door Open-Too-Long
alarm
" and stay in that mode unless the system is refreshed for other
(wait 2-3 seconds until the confirmation beeps are heard)
8901
" and stay in that mode unless the
(wait 2-3 seconds until the confirmation beeps are heard)
Multi-User Mode
; or vice versa. Just refresh
All the programmed data that saved
are set to
4 Digits
after the system is refreshed for Single
7
-- Set the above requirement into the keypad:
2) Programming
0000 *
---------------- Enter to programming mode with the factory-set Master Code
8900 #
---------------- System has been set for Single User Mode**
0 3289 #
------------ 3289 has been saved as the new Personal Master Code
1 8321 #
------------ 8321 has been saved as User Code 1, with Duress
2 6854 #
------------ 6854 has been saved as User Code 2
3 9270 #
------------ 9270 has been saved as User Code 3
40 1 #
---------------- Output 1 has been set in Momentary Mode, 1 second
51 #
-------------------- Output 2 has been set in Start / Stop Mode without accelerated code
62 #
-------------------- Output 3 has been set in Start / Stop Mode with accelerated code
72 10 #
-------------- The keypad has been set to lock during 15 minutes after 10 successive false
codes
81 #
-------------------- The keypad has been set with door Forced-Open-Alarm enabled
9 60 #
---------------- The keypad has been set with 60 seconds allowable time for door left open
*
--------------------------- Keypad exits programming mode. All the data above are saved and ready for use
NOTE:
a) **Enter the Single User Mode Command Code "8900" may not be necessary if the keypad was
already in Single User Mode.
b) In case of wrong entry during programming, cancel it with
enter.
3) Operate The Keypad
-- Taking the data programmed above as reference
a)
To command the output 1, 2 & 3, enter the corresponding codes into the keypad.
required.
8321
----------------- Output 1 activates for 1 second
6854
----------------- Output 2 starts (or stops)
9270
----------------- Output 3 starts (or stops)
b)
The
Duress Code
does not need to program. The keypad determines it automatically by increasing the
first digit of the
User Code 1 of Two units
For example:
The User Code 1 is "1234", then the Duress Code is "3234"; or the User Code 1 is
"8321", then the Duress Code is "0321".
To command the Duress Function, enter the Duress Code.
0321
----------------- Duress output activates (output switches to ground) & Output 1 activates for 1
second
NOTE:
i) The Duress Code has double actions. It activates the Duress Output and at the same time activates
the Output 1 as like the User Code 1. The Duress Code can always activates or deactivates (in Start
/ Stop mode) Output 1, but cannot deactivate (reset) the Duress Output. ONLY the User Code 1 can
deactivate (reset) the Duress Output.
ii) All alarms will be stopped, including the door forced-open-alarm and the door open-too-long alarm,
when Duress function is in operation.
&
Alarm OFF Code functions
#
key, or, wait 10 seconds, then re-