At Run-Time
The RESET/DEFAULT button can be used at run-time – you can press the button while the
TA7104i
is running without powering the unit off. Table 7 describes the actions you can perform in this
case.
Table 7: RESET/DEFAULT Button Interaction
RESET/ DEFAULT
Button Pressed for:
2 to 6 seconds
7 to 11 seconds
12 to 16 seconds
17 seconds and
more
At Start-Time
You can use the RESET/DEFAULT button at start-time – you power the unit off, and then
depress the button until the LEDs stop blinking and remain ON. This applies the "Factory Reset"
procedure (see Factory Reset). This feature reverts the TA7104i back to its default factory
settings.
© 2014 Aastra Sweden | 154_1531 ANF 901| A | 2014-05-15
Action
Restarts the
No changes are made to
TA7104i
the TA7104i settings.
Sets the TA7104i
Sets some of the TA7012i
in Partial
configuration to pre-
Reset Mode
determined values.
Restarts the
Deletes the persistent
TA7104i in
configuration, creates a
Factory Reset
new configuration file with
the default factory values,
and then restarts the unit.
No action is
The RESET/DEFAULT
taken
Button
Pressed event is ignored
Comments
25
TA7104i Hardware Installation
LEDs Pattern
Power LED:
blinking, 1Hz,
50% duty
All other LEDs:
OFF
All LEDs
blinking, 1Hz,
50% duty
All LEDs
steady ON
N/A