Reset/Default Button - Aastra TA710i Hardware Installation Manual

Table of Contents

Advertisement

LED Patterns – Default Behaviour
When no specific condition matches those described in Table 5, the LEDs behave individually
according to the following rules:
Table 6: Default LED Behaviour
LED Type
Power
ETH
ETH2
LED Type
In Use
Ready

RESET/DEFAULT Button

4.3
The RESET/DEFAULT button allows you to:
Cancel an action that was started.
Revert to known factory settings if the TA7104i refuses to work properly for any reason or
the connection to the network is lost.
3. Reconfigure a unit.
© 2014 Aastra Sweden | 154_1531 ANF 901| A | 2014-05-15
Condition
RestartInProgress
RestartCompleted
Network traffic
No network traffic
Network traffic
No network traffic
Condition
Lines Idle and Unlocked
Lines InUse and Unlocked
Shutting Down
Locked
All lines are enabled
(operational state).
All lines are disabled
(operational state).
At least one line is enabled and
at least one line is disabled
(operational state).
Behaviour
Blinking, 1 Hz, 50% duty
Steady ON
Blinking, variable rate
Steady ON
Blinking, variable rate
Steady ON
Behaviour
Steady OFF
Steady ON
Steady yellow
Blinking yellow, 1 Hz, 50% duty
Steady ON
Steady OFF
Blink 0.25 Hz 75%
24