1. With a 10/100 Hub and two 10/100 BaseT Ethernet RJ-45 straight cables, connect both
cables to the Hub; one of them is connected into the WAN connector. The other cable links
the computer to the Hub.
2. Reconfigure the IP address of your computer to 192.168.0.11 and the Subnet Mask to
255.255.255.0.
3. Restart the computer.
4. Power on the TA7104i, by connecting the other end of the power cord to an electrical outlet.
The electrical outlet must be installed near the TA7104i so that it is easily accessible.
5. Insert a small, unbent paper clip into the Reset / Default hole located at the rear of the
TA7104i. The Power LED will start blinking, and after a few seconds, all the LEDS will start
blinking. Release the paper clip after all the LEDs start blinking and before they all stop
blinking (between 7-11 seconds).
This procedure is called a partial reset. After a partial reset is performed, the TA7104i uses
the default IP address 192.168.0.1/24. Refer to "Partial Reset" for details on the partial reset
procedure.
The corresponding link-local IPv6 address is also available and printed on the sticker under
the TA7104i.
You can now access the TA7104i web interface. Refer to the Software Configuration Guide
for more details.
IPv6 Link Local Address Configuration
If there is no DHCPv6 server or IPv6 router in your network, you can use the link local address
to contact the unit. Note that the TA7104i IPv6 interface is disabled by default.
1. With a 10/100 Hub and two 10/100 BaseT Ethernet RJ-45 straight cables, connect both
cables to the Hub; one of them is connected into the WAN connector. The other cable links
the computer to the Hub.
2. Power on the TA7104i by connecting the other end of the power cord to an electrical outlet.
The electrical outlet must be installed near the TA7104i so that it is easily accessible.
3. Insert a small, unbent paper clip into the Reset / Default hole located at the rear of the
TA7104i. The Power LED will start blinking, and after a few seconds, all the LEDS will start
blinking. Release the paper clip after all the LEDs start blinking and before they all stop
blinking (between 7-11 seconds). This procedure is called a partial reset. After a partial
reset is performed, the TA7104i enables its link local IPv6 address. Refer to Partial Reset
for details on the partial reset procedure. The corresponding link-local IPv6 address is also
available and printed on the sticker under the TA7104i.
4. Proceed with accessing the TA7104i's web interface by using the unit's link local address.
The unit's link local address is printed on a sticker under the unit. The link local address can
be determined by using the following pattern: [fe80::290:f8ff:feXX:XXXX] where XXXXXX