SystemAir SUE 250EC Installation And Operating Instructions Manual
SystemAir SUE 250EC Installation And Operating Instructions Manual

SystemAir SUE 250EC Installation And Operating Instructions Manual

Supply air unit

Advertisement

Quick Links

Supply Air Unit
SUE
GB
Installation and Operating Instructions
Document in original language | 199495 · 001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SUE 250EC and is the answer not in the manual?

Questions and answers

Summary of Contents for SystemAir SUE 250EC

  • Page 1 Supply Air Unit Installation and Operating Instructions Document in original language | 199495 · 001...
  • Page 2 © Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their products without notice. This also applies to products already ordered, as long as it does not affect the previously agreed specifications. 199495 | 001...
  • Page 3: Table Of Contents

    Contents General information .........1 Notice symbols ........1 1.1.1 Instruction symbols.....1 Important safety information ......1 Personnel ..........1 Personal protective equipment....2 5 rules of electrical safety ......2 Warranty ............2 Delivery, transport, storage .......2 Description ............4 Intended use .........4 Incorrect use ........4 Technical data ........4 Name plate and type key ........5 Accessories............6 Installation.............7...
  • Page 5: General Information

    General information | General information Notice symbols Danger Caution Hazard with a low risk Direct hazard Failure to comply with this warning may lead to Failure to comply with this warning will lead moderate injuries. directly to death or to serious injury. Important Warning Hazard with risk of damage to objects...
  • Page 6: Personal Protective Equipment

    Further prerequisites are a completed maintenance plan with no gaps and a commissioning re- port. Systemair will require these in the case of a warranty claim. The commissioning report is a component of this document. The maintenance plan must be created by the operator, see section 12.2 Maintenance, page 12.
  • Page 7 Delivery, transport, storage | Unpacking When opening the transport packaging, there is a risk of damage from sharp edges, nails, staples, splinters etc. ♦ Unpack the fan carefully. ♦ Check the fan for obvious transport damage. ♦ Only remove the packaging shortly before assembly. Transport Safety information Warning: Electrical or mechanical hazards due to fire, moisture, short circuit or malfunction.
  • Page 8: Description

    | Description Description Intended use • The SUE is intended to provide rooms with pre-heated air. • The fans are intended for installation in ventilation systems. They can be installed both in duct systems and also with free suction via a suction-side contact protection grille. Free discharge via a contact protection grille is also possible. •...
  • Page 9: Name Plate And Type Key

    Name plate and type key | Possible adjustments The value can be adjusted, see manual of Temperature Factory the controller TCA setting: 20°C (attached to the SUE). The air volume can be S-5EC adjusted with the 5 5 steps- Air volume steps switch.
  • Page 10: Accessories

    | Accessories Accessories Note: For details of the accessories, please check our online catalog or contact Systemair. FFR/FGR Supply Air Unit Louvre Shutter Fast clamp Round protection grille Filter cassette Back draft damper Wall grid Filter cassette Protection guard Silencer...
  • Page 11: Installation

    Installation | Installation Safety information ♦ Observe 2 Important safety information, page 1 ♦ Check the surface before installation for load bearing capacity. ♦ Consider all static and dynamic loads when selecting hoisting equipment and fastening components. ♦ Provide contact and intake protection and ensure safety distances according to DIN EN ISO13857 and DIN 24167-1. Preconditions ♦...
  • Page 12: Electrical Connection

    | Electrical connection Electrical connection Safety information ♦ Observe 2 Important safety information, page 1 ♦ Prevent the ingress of water into the connection box. Connection ♦ Check if the data on the nameplate matches the ♦ Connect the cable end in a dry environment. connection data.
  • Page 13: Variable-Speed Fans

    Commissioning | If the overheating cut-out has been activated, observe *Reset- button the following steps 1. Observe the 5 rules of electrical safety, see 2.3 5 rules of electrical safety, page 2. 2. Investigate carefully the reason for activation of the cut-out.
  • Page 14: Troubleshooting/Maintenance/Repair

    Problem Possible causes Remedy Soiling on the impeller Clean carefully Material decomposition on the impeller due Contact Systemair to aggressive material conveyed. Impeller rotates in wrong direction. Contact Systemair Fan does not run Deformation of impeller due to excessive Ensure that the temperature does not exceed smoothly temperature.
  • Page 15 “Air output of fan too low” or “Motor does See “Air output of fan too low” or “Motor not rotate” –> airflow sensor disables the does not rotate” of this chapter heating Check if the filter Note: For all other damage/defects, please contact Systemair. 199495 | 001...
  • Page 16: 12.2 Maintenance

    Spare parts ♦ Use original spare parts from Systemair only. ♦ When ordering spare parts, please specify the serial number of the fan. This can be found on the name plate. Cleaning Safety information ♦...
  • Page 17: Deinstallation/Dismantling

    ♦ Disassemble the fan into its components. ♦ Separate the parts according to: • reusable material • material groups to be disposed of (metal, plastics, electrical parts, etc.) Product fiche SUE For more information in local language www.systemair.de Systemair Trade name Product No. 94729...
  • Page 18: Commissioning Report

    | Commissioning Report Commissioning Report Warranty claims can only be made if commissioning work is carried out correctly and written evidence thereof is provided. Description: Article no.: Manufacturing order no.: Installer Company: Contact person: Company address: Tel. no.: Email: Operator (Place of installation) Company: Contact person: Company address:...
  • Page 19: Eu Declaration Of Conformity

    Grille measurement acc. to VDI 2044 □ □ Commissioning of the fan successful? Date, installer's signature Date, operator's signature EU Declaration of conformity The manufacturer: Systemair GmbH Seehöfer Straße 45 97944 Boxberg Germany Product designation: Circular duct fans Type designation: prioAir, prioAir Silent...
  • Page 20 Systemair GmbH Seehöfer Str. 45 97944 Boxberg Germany Tel.: +49 (0)7930/9272-0 Fax: +49 (0)7930/9273-92 info@systemair.de www.systemair.de...

This manual is also suitable for:

94729

Table of Contents