IFM ecomatDisplay CR1058 Installation Instructions Manual

IFM ecomatDisplay CR1058 Installation Instructions Manual

Process and dialogue module

Advertisement

Quick Links

Installation instructions
Process and dialogue module
UK
ecomatDisplay
CR1058
CR1059

Advertisement

Table of Contents
loading

Summary of Contents for IFM ecomatDisplay CR1058

  • Page 1 Installation instructions Process and dialogue module ecomatDisplay CR1058 CR1059...
  • Page 2: Table Of Contents

    Process and dialogue module ecomatDisplay CR1058, CR1059 Contents 1 Preliminary note � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4 1�1 Key to the symbols �...
  • Page 3 Process and dialogue module ecomatDisplay CR1058, CR1059 7�2 CR1059 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 31 8 Maintenance, repair and disposal�...
  • Page 4: Preliminary Note

    Process and dialogue module ecomatDisplay CR1058, CR1059 1 Preliminary note Technical data, approvals, accessories and further information at www�ifm�com� 1.1 Key to the symbols ► Instruction > Reaction, result […] Designation of keys, buttons or indications → Cross-reference Important note Non-compliance may result in malfunction or interference�...
  • Page 5: Safety Instructions

    Process and dialogue module ecomatDisplay CR1058, CR1059 2 Safety instructions ● The device described is a subcomponent for integration into a system� The manufacturer is responsible for the safety of the system� The system creator undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system�...
  • Page 6: Functions And Features

    Process and dialogue module ecomatDisplay CR1058, CR1059 3 Functions and features The process and dialogue module ecomatDisplay is a programmable graphic display for controlling, parameter-setting and operation of mobile machines and plants� It is designed for use up to a height of 3,000 m above mean sea level even in difficult conditions such as increased temperature range and mechanical load, see (→...
  • Page 7: 3�2 Overview Of The Common Characteristics

    Process and dialogue module ecomatDisplay CR1058, CR1059 3.2 Overview of the common characteristics ● 5" colour display ● Closed metal housing suitable for panel mounting and surface mounting outside or in the cabin ● Freely programmable to IEC 61131-3 with target visualisation ●...
  • Page 8: Installation

    ● EC1410���EC1414, RAM Mount system for surface mounting ® You can find more information about the available accessories at: www�ifm�com 4.2 General installation instructions For all types of mounting the following applies: The system creator is responsible for ensuring compliance with the requirements concerning mounting of the device in the application with regard to shock, vibration, acceleration and weight�...
  • Page 9: 4�2�1 Locator For Mounting Accessories

    Process and dialogue module ecomatDisplay CR1058, CR1059 4.2.1 Locator for mounting accessories The back of the device has been prepared for fixing the mounting accessories� 38,1 1: 4 x M5 threaded hole for RAM Mount system / for the fixing profiles of the installation kit ®...
  • Page 10: 4�2�2 Light Sensor And Status Led

    Process and dialogue module ecomatDisplay CR1058, CR1059 4.2.2 Light sensor and status LED The device is equipped with a light sensor� This sensor is used for automatic brightness adaptation of the display and the operating elements to the ambient brightness�...
  • Page 11 Process and dialogue module ecomatDisplay CR1058, CR1059 WARNING! The housing does not meet the requirements concerning protective earth� It can only be connected to functional ground� > Electric shock possible in case of dangerous active voltages in the control cabinet behind the installation level�...
  • Page 12: 4�3�2 Integration With Installation Kit

    Process and dialogue module ecomatDisplay CR1058, CR1059 CAUTION! The use of the installation kit does not ensure the requirements concerning the protection rating of the system with the installed device� > Protection rating and electrical protection may be impaired ► The system creator has to ensure the protection rating depending on the requirements of his application, if necessary by means of external precautions�...
  • Page 13: 4�3�4 Mounting Steps

    Process and dialogue module ecomatDisplay CR1058, CR1059 4.3.4 Mounting steps ► Screw the set screws into the M5 threads on the back of the device� (→ 4.2.1 Locator for mounting accessories) ► Attach damping strip to the device� Damping strip ►...
  • Page 14: Mount System

    Process and dialogue module ecomatDisplay CR1058, CR1059 Mounting principle Installation depth A = device depth (approx. 48 mm) Installation depth with the attached connector: 1: M5 hexagon nuts approx. 72 mm 2: Fixing profile 3: Panel cutout 4: Spacer 5: Damping strip...
  • Page 15: 4�4�1 Mounting Steps

    Process and dialogue module ecomatDisplay CR1058, CR1059 4.4.1 Mounting steps ► Screw the mounting plate to the back of the device� Usable M5 thread depth: ≤ 8 mm Tightening torque M5: 5 ±0,5 ► Screw second mounting plate / ball of the selected RAM Mount component on ®...
  • Page 16: Electrical Connection

    Process and dialogue module ecomatDisplay CR1058, CR1059 5 Electrical connection ► Disconnect the machine from the mains supply before installation; if necessary, also disconnect any independently supplied input / output load circuits� The same applies to the M12 connectors! ► Observe the national and international regulations for the installation of electrical equipment�...
  • Page 17: 5�2 Connection Accessories

    Process and dialogue module ecomatDisplay CR1058, CR1059 5.2 Connection accessories You can find more information about the available accessories at: www�ifm�com 5.3 Connection technology Observe all notes on connection technology� ► Note the device label� ► Use M12 connectors with gold-plated contacts�...
  • Page 18: 5�4 General Wiring Information

    Process and dialogue module ecomatDisplay CR1058, CR1059 5.4 General wiring information Wiring of the connectors (→ 7 Technical data) 1: Supply, inputs/outputs (CR1059 only), video (CR1059 only), audio, CAN, ifm (CR1059 only), service 2: USB0 3: ETH0 Connector (back of the device) NOTE! Wrong connection may cause damage to the device�...
  • Page 19: 5�5 Operating Voltage And Fuses

    Process and dialogue module ecomatDisplay CR1058, CR1059 5.5 Operating voltage and fuses ► The individual electric circuits must be protected in order to protect the whole system� Automotive spade-type fuses are recommended� Description Connector 1 Operating voltage Nominal Required triggering...
  • Page 20: 5�7 Ethernet Interface

    Process and dialogue module ecomatDisplay CR1058, CR1059 Shield connection To avoid contact corrosion on the shield connection of the device, do not use any copper or nickel-plated materials for the bolting elements! ► In very corrosive environments such as extremely salty air, use screws with surface finishing on a zinc/nickel basis with thick-film passivation and sealing�...
  • Page 21: 5�9 Usb Interfaces

    Process and dialogue module ecomatDisplay CR1058, CR1059 5.9 USB interfaces Wiring (→ 7 Technical data) This USB interface is connected to a USB connector in the control panel or in the dashboard� It is used for the connection of USB 2�0 devices�...
  • Page 22: 5�9�1 Short-Circuit Protection

    Process and dialogue module ecomatDisplay CR1058, CR1059 5.9.1 Short-circuit protection NOTE! The USB interface (M12 connector) is not protected against short circuits with a live wire outside the following voltage ranges: +5 V DC -0.3...6.0 V DC (pin 1) –Data -0.3...3.6 V DC...
  • Page 23: 6�2 Getting Started

    Process and dialogue module ecomatDisplay CR1058, CR1059 6.2 Getting started ► Connect the device to the notebook/PC via the Ethernet interface� ► Switch on the notebook/PC; check the IP settings of the notebook/PC and change them if necessary� Internet protocol: TCP/IP IP address: 192.168.82.xxx (except for .247, s.a.)
  • Page 24: 6�5 Use Of The Internal Temperature Sensor

    Process and dialogue module ecomatDisplay CR1058, CR1059 6.5 Use of the internal temperature sensor The internal temperature sensor of the device can be read out with the software� The unit primarily heats up due to the following factors: ● solar radiation ●...
  • Page 25: Technical Data

    Contrast ratio typical 500:1 Character sets can be uploaded individually and are freely scalable preinstalled: ifm ISO fonts with vehicle-specifi c symbols, Arial, Courier Mechanical data Mounting variants panel mounting (control panel / control cabinet installation) with mounting handle surface mounting with RAM Mount system ®...
  • Page 26 Embedded Linux 4�14 Programming system CODESYS 3.5 (IEC 61131-3) Graphic functions via integrated target visualisation ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1058 / page 2 17�09�2020...
  • Page 27 Service inputs on power on SERVICE0 SERVICE1 Description normal start set-up recovery app 0 = GND 1 = VBB ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1058 / page 3 17�09�2020...
  • Page 28 ISO 16750-5 AA, BA, BD, CC, DB, DC, DD, ED, only one chemical permitted at a time ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1058 / page 4...
  • Page 29 AMP connector, 40 poles M12 connector socket , B-coded, socket 5 poles D-coded, 4 poles ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1058 / page 5 17�09�2020...
  • Page 30 +5 V DC -Data +Data housing = screen (4) ETH0 TxD+ RxD+ TxD- RxD- housing = screen ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1058 / page 6 17�09�2020...
  • Page 31: 7�2 Cr1059

    Contrast ratio typical 500:1 Character sets can be uploaded individually and are freely scalable preinstalled: ifm ISO fonts with vehicle-specifi c symbols, Arial, Courier Mechanical data Mounting variants panel mounting (control panel / control cabinet installation) with mounting handle surface mounting with RAM Mount system ®...
  • Page 32 Embedded Linux 4�14 Programming system CODESYS 3.5 (IEC 61131-3) Graphic functions via integrated target visualisation ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1059 / page 2 17�09�2020...
  • Page 33 Service inputs on power on SERVICE0 SERVICE1 Description normal start set-up recovery app 0 = GND 1 = VBB ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1059 / page 3 17�09�2020...
  • Page 34 ISO 16750-5 AA, BA, BD, CC, DB, DC, DD, ED, only one chemical permitted at a time ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1059 / page 4...
  • Page 35 AMP connector, 40 poles M12 connector socket , B-coded, socket 5 poles D-coded, 4 poles ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1059 / page 5 17�09�2020...
  • Page 36 +5 V DC -Data +Data housing = screen (4) ETH0 TxD+ RxD+ TxD- RxD- housing = screen ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen We reserve the right to make technical alterations without prior notice! CR1059 / page 6 17�09�2020...
  • Page 37: Maintenance, Repair And Disposal

    Process and dialogue module ecomatDisplay CR1058, CR1059 8 Maintenance, repair and disposal 8.1 Battery change Battery change only be qualified personnel ► Before changing the battery, fully separate the device from supply voltage� 1: Service cover 2: Battery ► Replace battery when time is permanently wrong after switch-on�...
  • Page 38: 8�2 Cleaning The Display Surface

    Process and dialogue module ecomatDisplay CR1058, CR1059 NOTE! No protection rating when service cover is open and no ESD protection on accessible contacts inside > Damage to the device possible ► Before opening, clean the area around the service cover�...
  • Page 39: 8�3 Cleaning The Housing Surface

    Process and dialogue module ecomatDisplay CR1058, CR1059 8.3 Cleaning the housing surface ► Disconnect the device� ► Clean the device from dirt using a soft, chemically untreated and dry cloth� ► In case of heavy dirt, use a damp cloth�...

This manual is also suitable for:

Ecomatdisplay cr1059

Table of Contents