Overview Of Units - Mitsubishi Electric PUMY-P200YKM2 Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PUMY-P200YKM2:
Table of Contents

Advertisement

2

OVERVIEW OF UNITS

2-1. SYSTEM CONSTRUCTION
Outdoor unit
Capacity
Applicable
Number of units
indoor unit
Total system capacity range
Branching pipe
components
Model
Cassette Ceiling
4-way flow
2 by 2
PLFY-P PLFY-P PLFY-EP *
Capacity
10
15VFM-E1
15
15VCM-E
20VFM-E1
20VBM-E
20
20VCM-E
20VEM-E
25VFM-E1
25VBM-E
25
25VCM-E
25VEM-E
32VFM-E1
32VBM-E
32
32VCM-E
32VEM-E
40VBM-E
40VFM-E1
40
40VCM-E
40VEM-E
50VBM-E
50VFM-E1
50
50VEM-E
63VBM-E
63VEM-E 63VLMD-E
63
63VEM-E
71
80VBM-E
80
80VEM-E
100VBM-E
100
100VEM-E
125VBM-E
125
125VEM-E
140
200
Note: Only for R1 models: PEFY-P·VMA(L)-E3, PKFY-P·VLM-E
Name
Model number
Remote
controller
Functions
1
*
PUMY is connectable to Fresh Air type indoor unit.
It is possible to connect 1 Fresh Air type indoor unit to 1 outdoor unit. (1:1 system)
Operating temperature range (outdoor temperature) for fresh air type indoor units differ from other indoor units.
Refer to "2-4-(3). Operating temperature range".
When the indoor unit of Fresh Air type is connected with the outdoor unit, the maximum connectable total indoor unit capacity is 110% (100%
2
*
in case of heating below −5: [23˚F]).
3
*
When connecting the CONNECTION KIT (PAC-LV11M-J) and an M-series indoor unit, refer to the installation manual for the CONNECTION KIT.
4
Authorized connectable indoor units are only as follows; PUMY-P200 : PEFY-P40VMA3 × 2 + PEFY-P63VMA3 × 2
*
Do not connect Lossnay remote controller(s). (PZ-61DR-E, PZ-43SMF-E, PZ-52SF-E, PZ-60DR-E)
5
*
Authorized connectable indoor units are only as follows; PLFY-EP63VEM-E × 3
6
*
OCH675D
CMY-Y62-G-E
Branch header
(2 branches)
Ceiling
Concealed
2-way flow 1-way flow
6
PLFY-P PMFY-P
PEFY-P
PKFY-P PCFY-P PFFY-P
15VMS1(L)-E 15VBM-E
20VMS1(L)-E
20VMA(L)-E
20VBM-E
20VLMD-E 20VBM-E
20VMA(L)-E3
20VMR-E-L/R
25VMS1(L)-E
25VMA(L)-E
25VBM-E
25VLMD-E 25VBM-E
25VMA(L)-E3
25VMR-E-L/R
32VMS1(L)-E
32VMA(L)-E
32VHM-E
32VLMD-E 32VBM-E
32VMA(L)-E3
32VMR-E-L/R
40VMS1(L)-E
40VMA(L)-E
40VHM-E
40VLMD-E 40VBM-E
40VMA(L)-E3
40VMA3-E*
4
40VMH-E
50VMS1(L)-E
50VMA(L)-E
50VHM-E
50VLMD-E
50VMA(L)-E3
50VMH-E
63VMS1(L)-E
63VMA(L)-E
63VMA(L)-E3
63VKM-E 63VKM-E 63VLEM-E
4
63VMA3-E*
63VMH-E
71VMA(L)-E
71VMA(L)-E3
71VMH-E
80VMA(L)-E
80VLMD-E
80VMA(L)-E3
80VMH-E
100VMA(L)-E
100VMA(L)-E
100VLMD-E
100VKM-E 100VKM-E
100VMA(L)-E3
100VMH-E
125VMA(L)-E
125VLMD-E
125VMA(L)-E3
125VMH-E
140VMA(L)-E
140VMA(L)-E3
140VMH-E
200VMHS-E
200VMH-E
M-NET remote controller
PAR-F27MEA-E
• A handy remote controller for use
in conjunction with the Melans
centralized management system.
• Addresses must be set.
8HP
PUMY-P200YKM2(R1)
PUMY-P200YKM2(R1)-BS
Type 10 to Type 200
1 to 12 unit
50 to 130% of outdoor unit capacity
CMY-Y64-G-E
Branch header
(4 branches)
Ceiling
Floor standing
Wall
Suspended
Mounted
Exposed Concealed Fresh air *
PFFY-P
10VLM-E
15VLM-E
20VLEM-E
20VLRM-E
20VLM-E
20VKM-E2
20VLRMM-E
25VLEM-E
25VLRM-E
25VLM-E
25VKM-E2
25VLRMM-E
32VLEM-E
32VLRM-E
32VLM-E
32VKM-E2
32VLRMM-E
40VLEM-E
40VLRM-E
40VLM-E 40VKM-E
40VKM-E2
40VLRMM-E
50VLRM-E
50VLEM-E
50VLM-E
50VLRMM-E
63VLRM-E
63VLRMM-E
125VKM-E
MA remote controller
PAR-21MAA, PAR-31/32MAA
• Addresses setting is not
necessary.
5
2
*
CMY-Y68-G-E
Branch header
(8 branches)
Ceiling
CONNECTION KIT
concealed
Lossnay
1
PAC-LV11M-J
5
PEFY-P
GUF *
M series indoor unit *
MSZ-GE series
MSZ-EF Series
MSZ-SF Series
MSZ-FH Series
50RD(H)4
MFZ-KJ Series
MSZ-LN·VG Series
MSZ-AP·VG Series
MSZ-AP·VF Series
100RD(H)4
200VMH-E-F
M series remote controller
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pumy-p200ykm2-bsPumy-p200ykm2r1Pumy-p200ykm2r1-bs

Table of Contents