5.2 CHANGEOVER FROM ONE GAS TO ANOTHER

Depending on the country foreseen for the installation and the category of the appliance (indicated on
the firm plate), the changeover from one gas to another may require 2 operations:
CI
Change nozzles (main burner, pilot burner and bypass
RA
Adjustment of primary air
PROCEDURE:
On the firm plate, check:
- The category (ies) of the equipment
- The gas and pressure for which it is adjusted.
In the following table, select:
- the country in question
- the gas and the category of the equipment (see above)
- the gas and pressure for which the equipment is going to be adjusted
- Follow and carry out the necessary operations
- Replace the adjustment plate (code no: 308875), and enter in the box the new gas used.

COUNTRIES

Austria
Finland – Sweden
Denmark
Belgium
Germany
Spain - Italy
United Kingdom
Ireland - Switzerland
Portugal
Spain - Switzerland
France
Luxemburg
Netherlands
Norway
*Change of category to be made only under the responsibility of our Company or our local agent.
GAS OF ORIGIN
(or new gas used)
Gas
P(mbar)
G 20
20
G 30
50
G 20
20
G 30
28-30
G 20
20
G 30
28-30
G 20
20
G 20 or G 31
20
G 30
50
G 20
20
G 25
20
G 30
50
G 20
20
G 30
28-30
G 20
20
G 20
20
G 20 or G 25
20/25
G 30
28-30
G 20 or G 25
20/25
G 20 or G 25
20/25
G 20
20
G 20
20
G 25
25
G 30
28-30
G 25
25
G 30
30
33
Page
NEW GAS
(or gas of origin)
Gas
P(mbar)
G 30 or G 31
50
G 31
50
G 30 or G 31
30/30
G 31
30
G 25
25
G 31
37
G 25
20
G 30 or G 31
50
G 25
20
G 31
50
G 30 or G 31
28-30/30
G 31
37
G 31
50
G 25
25
G 30 or G 31
28-30/37
G 31
37
G 30 or G 31
50
G 31
50
G 30 or G 31
50
G 31
50
G 30 or G 31
28-30/30
G 31
30
G 31
50
G 31
30
BONNET CIDELCEM GRANDE CUISINE
Siége social:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
3BE390582NI – 06/07
(See paragraph 5.4)
(See paragraph 5.4)
NECESSARY &
CATEGORY
AUTHORIZED
OPERATIONS
CI RA
II
2H3B/P
Nothing
CI RA
II
2H3B/P
Nothing
I
Nothing
2E+
I
Nothing
3+
CI
II
CI RA
2ELL3B/P
CI RA
I
3P
Change category
(see *)
CI RA
II
2H3+
Nothing
CI RA
II
2H3P
Nothing
II
CI RA
2E+3+
Nothing
II
CI RA
2E+3B/P
II
CI
2E+3P
II
CI RA
2E+3B/P
II
CI
2E+3P
CI RA
II
2L3B/P
Nothing
II
CI
2L3P
I
Nothing
3B/P
CI

Advertisement