Bonnet OPTIMUM 700 Builder’s Specifications page 30

Gas & electric boiling pans
Hide thumbs Also See for OPTIMUM 700:
Table of Contents

Advertisement

4.1 2 ELECTRIC BOILING PAN
Location of the equipotentiality terminal
Electric connection is carried out from the underside of the appliance on front, whatever the model is.
- Unscrew the fixation screw of the terminal strip support lug.
- Tilt towards the left.
- Introduce the cable through the gland.
- Tighten the gland.
- Connect the wires.
- Put the lug back in place.
- Connect the equipotential link to the terminal foreseen for the purpose.
• Only use supply cables of the H07 RN-F type with following section:
Voltages
230 V 3 a.c.
400 V 3N a.c.
A means of shut-off must be foreseen for fixed supply lines in compliance with the rules of installation.
The installation must meet the national rules in force (France: NFC 15.100).
The appliance must be connected to the earth. The different electric appliances must also be
connected by means of an equipotential line (all metallic structures to the same voltage) by means of a
terminal provided for this purpose and located beside the connecting gland.
The builder denies all responsibility in the case where the instructions above are not observed.
MA BM 60
MA CD 110
2
4 x 4 mm
4 x 6 mm
2
5 x 2.5 mm
5 x 4 mm
29
Page
MA BM 110
2
2
4 x 10 mm
2
2
5 x 6 mm
BONNET CIDELCEM GRANDE CUISINE
Siége social:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
3BE390582NI – 06/07
MA BM 150
MA BM 250
2
4 x 10 mm
2
5 x 6 mm
5 x 6 mm
-