Bonnet OPTIMUM 700 Builder’s Specifications page 16

Gas & electric boiling pans
Hide thumbs Also See for OPTIMUM 700:
Table of Contents

Advertisement

ELECTRIC connection
(Foresee a cable with 1.5 m free length)
HOT WATER
COLD WATER
SOFTENED WATER
GUTTER
MODEL
DIMENSIONS (mm)
Width x Depth x Height
Tank (depth x diameter)
Rated capacity
Maximum capacity
PACKAGING (mm)
Width x Depth x Height
WEIGHT (KG)
ELECTRICITY (Three-phase 230V+T or 400V+N+T)
Power (kW)
Max. intensity maxi (A)
HOT WATER
Pressure / Max. temperature
Connection
COLD WATER
Pressure
Connection
SOFTENED WATER
Pressure
Water hardness
Connection
GUTTER
TYPE OF APPLIANCE
ELECTRIC CONECTION
Electric outlet at 240 mm above the floor.
OPTIMUM 900, 110 litre electric boiling pan bain marie
230V 3a.c.
400V 3Na.c.
230V 3a.c.
400V 3Na.c.
Page 15
P075682
B-B906.MA.BM.110
800 x 920 x 1066
430 x ∅ 600
900 x 1110 x 1250
2.5/6 bars / 60°C
∅ 20/27 (3/4")
2.5/6 bars
∅ 20/27 (3/4")
2.5/6 bars
∅ 20/27 (3/4")
550 x 400 Mini
Back to the wall or another appliance
This document is not contractual; Edition 05/2007 – 3BE0487FT
BONNET CIDELCEM GRANDE CUISINE
Siége social:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
3BE390582NI – 06/07
100 litres
110 litres
18
18
45.2
26.1
70ppm