QUICK REFERENCE GUIDE
KI23400/KI27400 Series 2-Way Loss Test Meter
Revision 3
Date: 20 Nov 2020
Page 1 of 8

Advertisement

loading
Need help?

Need help?

Do you have a question about the KI23400 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingfisher KI23400 Series

  • Page 1 QUICK REFERENCE GUIDE KI23400/KI27400 Series 2-Way Loss Test Meter Revision 3 Date: 20 Nov 2020 Page 1 of 8...
  • Page 2 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter General Operation: • To return to Home menu, press F1. • To remove interchangeable connector adaptor, press button Meter Menu: on front of case and pull off adaptor. This may be easier with •...
  • Page 3 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter • To show sources’ nominal power levels, hold down Toggle To select modulation while source is on, press and release F3. Repeatedly press this button to scroll & select a tone Centre. frequency or ID-tone.
  • Page 4 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter • then press Toggle Centre to change between ‘in’ To record data to internal memory in Meter or Autotest mode, press triangular button above [STORE]. Data will be (activated) or ‘out’ (deactivated). stored in the next empty location.
  • Page 5 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter • • [For data saved in 1-way Autotest mode only]: To toggle To retest: Press F3 (Meter mode) or F4 (Autotest mode) to display to show absolute power in dBm or in both dBm and return to data acquiring mode.
  • Page 6 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter • To downloaded from KITS reporting software Loss test status for each wavelength will be shown with a • Refer to instruction in the software manual. ✓ ‘ ’ (pass) or ‘X’(fail) or blinking ‘X’ (marginal) on LCD. ORL (2-way Autotest only) test status for each wavelength will be To set up directly on the instrument ✓...
  • Page 7 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter • • To end the operation (on source unit), press and hold F3, Press - or + to find required Tag, then press Toggle Centre. Alternatively, press and hold F3 • Press F2 to confirm or F1 to cancel selection. for 3 sec.
  • Page 8 Quick Reference Guide: KI23400/KI27400 2-way Loss Test Meter User Calibration (UCAL): Instrument Data Sanitization: • To erase all parts of the non-volatile user memory, including user At Home menu, press F2 to enter ORL mode. data, and restore default instrument settings: •...