SunStar HC Series User Manual page 57

Dual function
Table of Contents

Advertisement

Error Type
Bad Color
Incorrect position of needle
Change
stop
Failure to sense signals for
needle position or 1 rotation
Incorrect position of needle
bar
Incorrect position of take-up
lever
Fuse failure for color
change motor
Bad connection
Cause
Refer to user's manual
Run manual color change and
check if signal lamps (needle
set lamp & needle position
lamp) blinks at correct needle
position. Adjust the half-turn
film.
Set it to the correct position
Adjust so take-up lever is in line
with other levers in stop position
(upper shaft angle:100°)
Change fuse F3 in joint board
or check connection
Inspection & Repair
Reference
Set main shaft angle back at
100°, if you manually moved
it for cleaning, inspection or
repair.
Unscrew the lever and
adjust so it is in line with
the others on the guide
rail.
Thread take-
up driving
lever fixing
screw
Thread
take-up
Check fuse spec.