Figure 4
8. To lock the access point to the mounting bracket, insert the T6 M2 x 6mm pan head screw into the hole
beside the button, located at the bottom of the mount, then tighten the screw until it is snug.
9. After the access point is securely fastened to the mounting bracket, connect the Ethernet cable(s) to the
appropriate RJ45 couple port(s) on either side of the mount.
Installing the Mount Housing onto a Wall Box
1. Align the holes on the mounting bracket with the corresponding holes on the wall box. To install this kit to a
single gang wall box, refer to
2. Use the #6-32 x 1/5" slotted screws to fasten the mount housing to the wall box using the corresponding
holes shown in
Figure 5
AP-220-MNT-W3
| Installation Guide
Securing the access point to the mounting bracket
Figure
Figure
5.
Installing the mounting bracket to a single-gang wall box
5. To install this mount kit to a dual gang wall box, refer to
Figure
6.
3