– The busy signal is not detected and the call is not ended by the
device.
Set the surroundings (affects the surroundings of the device).
– Via the TFS Set app (in menu Extended > Door conversation)
– Via an internal telephone
Change the volume of the loudspeaker.
– Via the device
– Via an internal telephone

Intercom

The device can be called from any internal telephone using its internal desti-
nation number. The call is signalled to the device by means of a recurring
signal sound. An additional bell can also be installed and switched on.
Options for call acceptance from the device:
Immediate (0 seconds): The voice connection is established automati-
cally and immediately.
Automatic according to timing (5 to 85 seconds): The voice connection
is established by pressing any door bell button within the set time
period. Once the set time period has elapsed, the call connection is
established automatically.
Manual (90 seconds): The voice connection is established by pressing
any door bell button within the set time period. The call is ended if no
door bell buttons are pressed within the set maximal call duration.
Note: The device accepts the call immediately as long as it is in
configuration mode (4 minutes). Only once this period of time has
elapsed can the call be handled as defined in the settings.