Function buttons explanation
For the incubators with item no. 51074 and 51075
The incubator has three buttons which are required for the incubator operation. The buttons and their
possible combinations will be explained in the following paragraph. Before operating the incubator, en -
sure that it is properly plugged into the according area.
The buttons are positioned as follows from left to right (green and round) in the centre of the operating
panel: "set", "+" and "–".
Set: This button allows to set the incubator basic temperature.
Push the button once shortly: Adjustment of the basic temperature (parameter ID: PP).
By activating the "+" and "–" buttons, the desired temperature can be adjusted, another
push of the "set" button allows the entered value to be saved.
Keeping the "set" button pushed: This will lead you into the menu to adjust the basic para-
meter (see table 3).
By activating the "set" button again, the various parameters can be selected.
If you wish to alter a parameter, push the "+" and "–" button to adjust the value shown up-
wards or downward. By pushing the "set" button again, the value is saved.
Display 2 will show each parameter via a number/letter combination (parameter ID).
Display 1 will show the changeable data.
Basic parameters
Turning frequency
Turning duration
Temperature calibration
Humidity calibration
Display of days
Table 3: Adjustment of the basic parameters via the "set" button
Holding "set "and "+" at the same time will let you enter the menu for fine adjustments
(see table 4).
By activating the "set" button again, the various parameters can be selected.
If you wish to alter a parameter, push the "+" and "–" button to adjust the value shown
upwards or downwards. By pushing the "set" button again, the value is saved.
Display 2 will show each parameter via a number/letter combination (parameter ID).
Display 1 will show the changeable data.
Finer parameters
Temperature alarm
too high
Heating stop
© by WilTec Wildanger Technik GmbH Item 50039, 50041, 51074–51077, 51271–51274
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Parameter
Adjustment range
ID
F1
0–999 min
F2
0–999 sec
F3
According to thermometer
F4
According to hygrometer
F5
0–99
Parameter
Adjustment range
ID
P1
0–99.9°C
P2
0–99.9°C
Standard
setting
120 min
15 sec
Remember to set the display of
days after every breeding back
to 0. The incubator will not do it
automatically.
Stand-
Note
ard set-
tings
38.6°C
37.8°C
Please note that the radiator
will switch off when reaching
the entered value, but will still
Note
When selecting
0 minutes, there
will be no turn-
ing
When selecting
0 minutes, there
will be no more
turning
Page 12