3. Configure the IP address of the external computer using the following: 10.2.<chassis>.<x>.
The <chassis> parameter represents the shelf address (the physical location of the shelf within
a central office). For the <x> variable, select a value from the range 17‐254 (for example,
10.2.<chassis>.17 to 10.2.<chassis>.254). Set the subnet mask for the interface to
255.255.0.0.
4. From the external computer use a Telnet connection to access the eth1:0 interface on the
MRM. The static IP address is: 10.2.<chassis>.<slot>.
The <chassis> parameter represents the shelf address, and the <slot> parameter represents
the MRM's location in the shelf.
The ATCA‐9100 login prompt will display. If the prompt does not display, verify the Telnet
connection to the IP address is correct.
5. Log in as
configuration procedures. To log off the MRM at any time, enter the
6. Disconnect the Ethernet cable from the Base Ethernet port on the hub module you connected
through when you are done performing the configuration procedures.
Verify Ethernet switch operation
Use these steps to view port status and to enable ports on the Base Ethernet and Fabric Ethernet
switches.
View port status
1. Verify you are at this prompt.
ATCA‐9100#
If you are not at the appropriate prompt, see Connect to an external computer and the
network on page
2. Enter the applicable command for the switch you are verifying.
Switch
Base Ethernet
Fabric Ethernet
3. Enter this command to show the status of the ports.
show port all
View the port status information to see which ports are enabled (EKey Mode and Admin
Mode) and connected to a peer (Link Status). If needed, press the space bar to view more of
the list.
4. Proceed to the applicable section or step:
•
To enable or disable specific ports, see Enable or disable specific ports on page
• To keep the default settings, continue with step 5.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
to get the
admin
ATCA‐9100#
5 for instructions on how to get there.
Command to enter
base‐ethernet
fabric‐ethernet
prompt. From this prompt you can perform
Verify Ethernet switch operation
command.
exit
Resulting prompt
ATCA‐9100‐Base#
ATCA‐9100‐Fabric#
8.