d. To enable another port, enter the 
in steps b and c. 
When finished enabling ports, enter this series of commands to return to the 
ATCA‐9100#
exit
exit
exit
If you are asked to save changes, enter 
configuration will be saved as the startup configuration. 
3. Enter the 
Power up and load software to the DSP devices
By default the DSP farms are powered off and no software is loaded on the DSP devices. The 
procedure initializes the serial RapidIO (sRIO) switch in order to access the DSP devices. The 
procedure loads the supplied diagnostics software to verify the DSP devices can load a known 
software image.
To power up the DSP farms and devices and load software to them:
1. Verify you are at this prompt.
ATCA‐9100#
If you are not at this prompt, see Connect to an external computer and the network on page
for instructions on how to get there. 
2. Access the Linux shell:
linux‐shell
3. Identify the kernel version in the directory path:
ls ‐d /lib/modules/*mrm1
The output should look similar to this and will be used for 
/lib/modules/2.6.14.7‐105mrm1
4. Load the library for the sRIO switch, using the base path from the previous step:
insmod <base_path>/kernel/drivers/rapidio/riodev.ko
For example:
insmod /lib/modules/2.6.14.7‐105mrm1/kernel/drivers/rapidio/riodev.ko
5. Initialize the sRIO switch:
sriotool init
6. Power up the DSP farms:
sriotool fpon 0
sriotool fpon 1
The DSP LEDs become red.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
prompt. 
 command again, to log off the module. 
exit
Power up and load software to the DSP devices
 command and perform the procedures described 
exit
 for yes or
 for no. If you choose
y
 n
<base_path>
for yes, this 
 y
 in the next step:
9

Advertisement

Table of Contents
loading

Table of Contents