All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches].
Unless otherwise specified, dimensions have a tolerance of ±0.13 mm [±.005 in.] and angles have a tolerance of ±2°. Figures
and illustrations are for identification only and are not drawn to scale.
1. INTRODUCTION
This specification covers the requirements for application of Quadrax DSub Connectors and Quadrax Contacts.
The Quadrax DSub Connectors consist of a four-position free hanging/ panel-mount plug, a right-angle printed
circuit (pc) board mount receptacle, and a free-hanging receptacle.
The Quadrax Pin and Socket Contacts shall be applied to appropriate Quadrax cables. The contact assembly
contains an outer shell, a one-piece dielectric, and four signal contacts. An inner crimp ferrule is included with
the cable applied contacts, and an optional sealing boot/plug is also available. These Quadrax Contacts may
also be used in other connector systems such as ARINC 600 Connectors, and MIL-DTL-38999 style
connectors. Contact TE Connectivity Product Engineering for specific application requirements for these other
product lines.
When corresponding with TE Personnel, use the terminology provided in this specification to facilitate inquiries
for information. Basic terms and features of this product are provided in Figure 1.
NOTE: Figures and illustrations are for
reference only and are not drawn to scale.
Pin Insert Dielectric
Pin Shell
© 2014 TE Connectivity family of companies
All Rights Reserved
*Trademark
TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
Quadrax DSub Connectors
and Quadrax Contacts
Pin Contact
Slot
Slot
Positioning Key
Socket Shell
Wiring Key (Index Line)
Figure 1
TOOLING ASSISTANCE CENTER 1-800-722-1111
PRODUCT INFORMATION 1-800-522-6752
Cable Not
Included in Kit
Socket Contact
Socket Insert
Dielectric
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at www.te.com.
Application Specification
114-13233
11 APR 14
Rev B
Inner Ferrule
Wire Sealing
Boot (Optional)
1 of 13

Advertisement

loading

Summary of Contents for TE Connectivity Quadrax DSub

  • Page 1 All Rights Reserved PRODUCT INFORMATION 1-800-522-6752 For latest revision and Regional Customer Service, *Trademark visit our website at www.te.com. TE Connectivity, TE connectivity (logo), and TE (logo) are trademarks. Other logos, product, and/or company names may be trademarks of their respective owners.
  • Page 2: Reference Material

    Reference Product Base Part Numbers 1445692, 2000314, and Product Code H723 are representative numbers of Quadrax DSub Connectors and Contacts. Use of these numbers will identify the product line and help you to obtain product and tooling information. Such information can be obtained through a local TE Representative, by visiting our website at www.te.com, or by calling PRODUCT INFORMATION or the...
  • Page 3 114-13233 Prolonged exposure to ultraviolet light may deteriorate the chemical composition used in the product material. B. Shelf Life The contacts and connector kits should remain in the shipping containers until ready for use to prevent damage. These products should be used on a first in, first out basis to avoid storage contamination. C.
  • Page 4 114-13233 Positioning Key Wiring Key (Index Line) Standard Cavity Number Assignment Socket Contact Mating Face Pin Contact Mating Face Positioning Key Wiring Key (Index Line) Reverse Cavity Number Assignment Pin Contact Mating Face Socket Contact Mating Face Socket-to-Socket Arrangement Pin-to-Pin Arrangement Pin Contact Mating Socket Contact Mating Socket Contact Mating...
  • Page 5 114-13233 A. Installation of Quadrax Pin Contact Assemblies in Receptacle Connectors Line up the positioning key with the internal key on the connector. Install the pin shell sub-assembly into the receptacle assembly until the pin shell snaps in place. Insert wire seal until flush with rear surface of housing.
  • Page 6 114-13233 3.10. Installation of Backshell Assembly (See Figure 5) Place one side of the backshell on the back of the connector aligning the rib on the housing with the groove in the backshell. Make sure that the backshell is on top of the last gland of the sealing boot/plug. NOTE Make sure the screw threads are recessed into the strain relief clamp to prevent interference with the housing during assembly.
  • Page 7 114-13233 3.11. Removal of Quadrax Contacts from Plug and Receptacle Connector Assemblies (RR/RR) Use recommended Extraction Tool 1738894-1 for removal of the pin or socket contacts from the plug or receptacle connector assemblies. Refer to Figure 6. Cut wire tie and remove backshell by loosening the captive screws. Slide sealing boot back up the cable and out of the way.
  • Page 8 114-13233 Screw Retainer Kit 211883-5 Screwlock Right-Angle PC Board Receptacle Cable Plug Figure 7 NOTE Panel thickness is 1.52-1.65 mm [.060-.065 in.]. (Figure 8) b. Free Hanging Plug (1) Install two flat washers on the screwlock and insert the screwlock through the front of the connector flange.
  • Page 9 114-13233 3.13. PC Board Connectors A. PC Board Material and Thickness PC board material may be glass epoxy (FR-4, G-10), or other TE Engineering approved substrates. The pc board contact can be installed on various thickness of pc board. Board thickness may vary depending upon the application, however, contact tail length through the pc board becomes important for wave soldering operations.
  • Page 10 114-13233 Board Thickness 1.60 [.063] Nominal Pad Diameter (As Required) Tin or Tin/Lead Thickness (As Required) Dia of Finished Hole After Plating 1.07 [.040] Min● Copper Thickness (As Required) (Maximum Drilled Hole Diameter (As Required) Hardness of Copper to be 150 Knoop) ●Ground Legs 1.65 [.065] Min.
  • Page 11 114-13233 DANGER Consideration must be given to toxicity and other safety requirements recommended by the solvent manufacturer. Refer to the manufacturer's Material Safety Data Sheet (MSDS) for characteristics and handling of cleaners. Trichloroethylene and Methylene Chloride can be used with no harmful effect to the connectors; however TE does not recommend them because of the harmful occupational and environmental effects.
  • Page 12 Terminated contacts and ferrules must not be re-terminated. 4. QUALIFICATION Quadrax DSub Connectors and Quadrax Contacts are not required to be agency evaluated and tested. 5. TOOLING Quadrax Contacts and ferrules can be terminated using hand crimping tools that accommodate the wire size specified.
  • Page 13 114-13233 6. VISUAL AID The illustration below shows a typical application of Quadrax DSub Connectors and Contacts. This illustration should be used by production personnel to ensure a correctly applied product. Applications which DO NOT appear correct should be inspected using the information in the preceding pages of this specification and in the instructional material shipped with the product or tooling.

This manual is also suitable for:

Quadrax2000739-1