Page 1
IMPORTANT: Read all instructions in this manual before operating pump. As a result of Burks® Pumps constant product improvement program, product changes may occur. As such Burks Pumps reserves the right to change product without prior written notification. PUMPS & SYSTEMS A Crane Co. Company...
SAFETY FIRST! Please Read This Before Installing Or Operating Pump. This WARNING ! Do not pump hazardous materials information is provided for SAFETY and to PREVENT EQUIPMENT (flammable, caustic, etc.) unless the pump is PROBLEMS. To help recognize this information, observe the specifically designed and designated to handle them.
No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, without our prior written approval. Crane Pumps & Systems, Inc., Burks Pumps Division PUMPS & SYSTEMS 420 Third Street • Piqua, Ohio 45356-0603 • Phone: (937) 778-8947 • Fax: (937) 773-7157...
SECTION A: GENERAL INFORMATION SECTION B: INSTALLATION RECOMMENDATIONS: A-1) To the Purchaser: B-1) Location: Locate the pump as close to the source of supply as possible. Although the pump will operate on suction lifts of 25 feet, it Congratulations! You are the owner of one of the finest is desirable to keep the suction lift less than 15 feet, if pumps on the market today.
Use a strainer on suction line to prevent the entrance of 4. The discharge of a self priming centrifugal pump may be oversize solids. This strainer should be submerged deep closed briefly without damaging the pump. However, the enough to prevent air from being drawn into the suction line, water will soon heat up and this can damage the pump thus reducing the pump’s capacity and pressure.
Page 7
2A- Buna-N Seat Cup 3 - Stainless Retainer 4 - Stainless Drive Band 5 - Stainless Spring 6 - Stainless Springholder 7 - Crane-Carb® Mating Ring 7A- Carbon Mating Ring 8 - Buna-N Bellows Cross Section of Seals. Two Styles Shown.
TROUBLE SHOOTING CHART SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Little or no discharge 1.Casing not filled with water 1.Fill pump casing. Using a foot-valve will extend pump life and facilitate immediate priming. and unit will not prime 2.Total head too high 2.Shorten suction head.
SECTION E: REPLACEMENT PARTS E-1 ORDERING REPLACEMENT PARTS: When ordering replacement parts, ALWAYS furnish the following information: 1. Pump serial number and date code. 2. Pump model number. 3. Pump part number. 4. Part description. 5. Item part number. 6. Quantity required. 7.
RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A "RETURNED GOODS AUTHORIZATION". CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
Need help?
Do you have a question about the burks pumps WB4 and is the answer not in the manual?
Questions and answers