Appendix: Specifications - Tyco Visonic SD-304C PG2 Installation Instructions Manual

Powerg, wireless shock and contact detector with wired input

Advertisement

W.E.E.E. Product Recycling Declaration
For information regarding the recycling of this product you must contact the company from which you orignially purc hased it. If you are disca rd in g t h is p ro d u ct a nd n o t
returning it for repair then you must ensure that it is returned as identified by yo ur supplier. This product is not to be thrown away with everyday waste.
Directive 2012/19/EU Waste Electrical and Electronic Equipment.

APPENDIX: SPECIFICATIONS

Frequency Band (MHz)
Communication Protocol
Alarm Input
Tamper
Supervision
Tamper Alert
Power Supply
Battery type
Battery Life Expectancy
Low Battery Threshold
Current Consumption
Shock Detection Radius and
Sensitivity Level
Operating Temperature
Storage Temperature
Humidity
Auxiliary Input Cable Length
Auxiliary Input EOL Resistor
Dimensions (LxWxD)
Weight (including battery)
D-304286 SD-304C PG2 Installation Instructions
in a particular installation. If this device does cause such interf erence, which can be verif ied by turning the
device of f and on, the user is encouraged to eliminate the interf erence by one or more of the f ollowing
measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit dif ferent f rom the one which supplies power to the receiver.
Consult the dealer or an experienced rad io/TV technician
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de la classe B est conf orme a la norme NMB -003 du Canada.
WARNING!
To comply with FCC and IC RF exposure compliance requirements, the device should be located at a
distance of at least 20 cm f rom all persons during normal operation. The antennas used f or this product must
not be co-located or operated in conjunction with any other antenna or transmitter.
WARNING!
The user is cautioned that changes or mo dif ications to the unit, not expressly approved by Visonic Ltd., could
void the user's FCC or other authority to operate the equipment.
Wood
Supports
Opening
Closing
Direction
20mm+/-
15mm+/-
5mm
5mm
15mm+/-
13mm+/-
5mm
5mm
26mm+/-
24mm+/-
5mm
5mm
Europe and rest of world: 433-434, 868-869 USA: 912-919
PowerG
One auxiliary
Front and back
Signaling at 4-min. intervals
Reported when a tamper event occurs
Type C
3 V Lithium CR-123A type battery, Panasonic, Sanyo or GP only.
5 years (f or typical use) with all sensors enabled
2.6 V
20 – 30 A approx. (150 mA during transmission)
Not EN Tested
Plate material
Shock detection
radius
Window
Wood
Brick/concrete
walls
-10C to 55C (14F to 131F)
-20C to 60C (-4F to 140F)
Average relative humidity of approximate 75% non-condensing. For 30 days per year relative humidity may
vary between 85 % and 95 % non-condensing
10m max.
2.2 KΩ
118 x 27 x 30 mm (4-5/8 x 1-1/8 x 1-3/16 in.)
130g (4.6 oz)
Soft Iron
Opening
Closing
11mm+/-
X
13mm+/-5mm
5mm
12mm+/-
Y
14mm+/-5mm
5mm
24mm+/-
Z
26mm+/-5mm
5mm
Plate material
4M
Framed glass window
(standard test material
A1)
3.5M
Wooden plate
(Standard test material
A2)
2.5M
Concrete plate
(Standard test material
A3)
Figure 5: Axis Definitions
EN Certified
Shock
Sensitivity level
detection
radius
1M
15
1M
12
0.5M
4
5