Maintenance; Specification - STIEBEL ELTRON DHE Connect 18/21/24 Operation And Installation

Hide thumbs Also See for DHE Connect 18/21/24:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION

Maintenance

16. Maintenance
WARNING Electrocution
Before any work on the appliance, ensure omnipolar
disconnection from the power supply.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
f Close the 3 way ball shut-off valve or the shut-off valve in the
f
cold water supply line.
f Open all draw-off valves.
f
f Undo the water connections on the appliance.
f
f Store the dismantled appliance in a room free from the risk
f
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
Cleaning the strainer
If dirty, clean the strainer in the threaded cold water fitting. Close
the 3 way ball shut-off valve or the shut-off valve in the cold water
supply line before removing, cleaning and refitting the strainer.
www.stiebel-eltron.com 

17. Specification

17.1 Dimensions and connections
225
140
b02
20
100
c06
DHE Connect | DHE Touch  |
≤ 20
105
35
c01
101