Connector Input/Output Signals - Sony WLL-RX55 Maintenance Manual

Wireless camera receiver
Hide thumbs Also See for WLL-RX55:
Table of Contents

Advertisement

1-2. Connector Input/Output Signals

DC-IN (4P MALE)
1
(External view)
No.
Signal
1
GND
2
NC
3
NC
4
+12 V
DC OUT 12V (4P FEMALE)
1
2
(External view)
No.
Signal
1
UNREG GND
2
NC
3
NC
4
UNREG +12 V
AUDIO OUTPUT CH-1/2 (XLR 3P, MALE)
1
(External view)
No.
Signal
1
MIC OUT (G)
2
MIC OUT (X)
3
MIC OUT (Y)
1-2 (E)
4
2
3
Specifications
GND for UNREG IN
DC 10.5 to 17 V
4
3
Specifications
GND for UNREG +12 V
DC 10.5 to 17 V
2
3
(0 dBu = 0.775 Vrms)
Specifications
0 dBu/_20 dBu
(Selectable with the Setup
menu)
MIC REMOTE (D-SUB 15P, FEMALE)
8
15
(External view)
No.
Signal
+5.5 V OUT
1
2
AUX4 (IN/OUT)
TALLY GND
3
AUX2 (IN/OUT)
G TALLY OUT
4
AUX1 (IN/OUT)
R TALLY OUT
5
CHU MIC
CONT2
6
AMP
CONT1
7
GAIN IN
CONT0
8
MIC1/2 GAIN CONT
1 IN
9
GND
10
AUX3 (IN/OUT)
TALLY OUT
11
AUX5 (IN/OUT)
12
16:9/4:3
SELECT EN IN
13
16:9/4:3
SELECT IN
14
AUX9 (IN)
15
MIC1/2 GAIN CONT
2 IN
*1 : CHU MIC AMP GAIN
CONT0
CONT1
CONT2
H
H
H
L
H
H
H
L
H
L
L
H
H
H
L
*2 :
8pin
15pin
L
L
L
H
H
L
H
H
1
9
Specifications
Max. 70 mA
GND for TALLY
ON (GND) : Max. 30 mA IN
ON (GND) : Max. 30 mA IN
*1 Refer to the following column.
*2 Refer to the following column.
GND for +5.5 V
R/G TALLY OUT
ON (GND) : Max. 30 mA IN
Enable : Low (GND)
Disable : Open or High (+5V)
Enable : Low (GND)
Disable : Open or High (+5V)
*2 Refer to the following column.
CHU MIC AMP GAIN
60 dB
50 dB
40 dB
30 dB
20 dB
MIC GAIN CONT
MIC 1 and 2 ON
MIC 1 ON
MIC 2 ON
INTERNAL set
WLL-RX55