Daikin BRC7M675 Operation & Installation Manual page 25

Wireless remote controller and wireless receiver kit
Table of Contents

Advertisement

3. Attach the included receiver assembly (1)
to the 2 tabs on the indoor unit, as per the
figure.
Tab
Tab
Receiver assembly (1)
4. Connect the wire harnesses which were
connected to the transmission printed
circuit board (2) in step 1. as follows.
• Wire harness - long (3) to connector
X24A on the indoor unit printed circuit
board
• Wire harness - short (4) to connector
CN1/X1A on the receiver assembly (1)
Connector (X24A)
(Black)
Connect
firmly to the
connector.
Wire harness -
long (3)
Receiver assembly (1)
Indoor unit printed
circuit board
Connect firmly
to the connector.
Wire harness -
short (4)
Connector
(CN1/X1A)
22