Daikin BRC7M634F Operation Manual
Daikin BRC7M634F Operation Manual

Daikin BRC7M634F Operation Manual

Wireless remote controller kit

Advertisement

Wireless Remote Controller Kit
MODELS:
BRC7M634F/K
BRC7M635F/K
Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air conditioner.
It will tell you how to use the unit properly and help you if any trouble occurs.
After reading the manual, file it away for future reference.
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRC7M634F and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin BRC7M634F

  • Page 1 MODELS: BRC7M634F/K BRC7M635F/K Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file it away for future reference.
  • Page 2 COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH...
  • Page 3: Prior To Use

    PRIOR TO USE This operation manual is exclusively for instructions on how to use the wireless remote controller. Read also the operation manual attached to the indoor unit for safe usage of the system and maintenance.
  • Page 4  Disposal requirements Your product and the batteries supplied with the controller are marked with this symbol. This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste. For batteries, a chemical symbol can be printed beneath the symbol.
  • Page 5: Table Of Contents

    CONTENTS After reading, keep this manual in a convenient place so that you can refer to ILLUSTRATION ........[1] it whenever necessary. If the equipment PRIOR TO USE ........[2] is transferred to a new user, be sure also to hand over the manual. 1 SAFETY PRECAUTIONS.....
  • Page 6 Consult your local dealer regarding what Do not use the product in the atmosphere to do in case of refrigerant leakage. contaminated with oil vapor, such as When the air conditioner is to be installed cooking oil or machine oil vapor. in a small room, it is necessary to take Oil vapor may cause crack damage, proper measures so that the amount of...
  • Page 7 After prolonged use, check the unit The batteries must be removed from stand and its mounts for damage. the appliance before it is scrapped and they are disposed of safely. If left in a damaged condition, the unit may fall and cause injury. Arrange the drain to ensure complete Do not place flammable sprays or drainage.
  • Page 8: What To Do Before Operation

    Do not leave the remote controller DISPLAY “ ” wherever there is a risk of wetting. (PROGRAMMED TIME) If water gets into the remote controller there is a risk of electrical leakage and This display shows PROGRAMMED damage to electronic components. TIME of the air conditioner start or stop.
  • Page 9: Handling For Wireless Remote Controller

    NOTES FILTER SIGN RESET BUTTON • For the sake of explanation, all indications Refer to the section of MAINTENANCE are shown on the display in Figure 1 in the operation manual attached to the indoor unit. contrary to actual running situations. •...
  • Page 10 Installation site • It is possible that signals will not be received in room that have electronic fluorescent lighting. Please consult with your local dealer before buying new fluorescent lights. • If the remote controller operated some 2 short beeps other electrical apparatus, move that from the receiver machine away or consult your local dealer.
  • Page 11: Operation Range

    〈〈 FOR SYSTEMS WITHOUT COOL/ In this case, contact your DAIKIN dealer. HEAT CHANGEOVER REMOTE CONTROL SWITCH 〉〉 5. OPERATION RANGE Refer to figure 1-1, 2 on page [1]...
  • Page 12 Refer to figure 1-1,3 on page [1] <Example> When the indoor temperature decreases OPERATION MODE to 23°C or less when the set temperature SELECTOR is at 25°C in the AUTOMATIC COOLING OPERATION, the operation is changed (1) Select OPERATION MODE with the over to the AUTOMATIC HEATING COOL/HEAT CHANGEOVER REMOTE OPERATION.
  • Page 13 AT THE START OF OPERATION AND CHARACTERISTICS OF THE AFTER DEFROST OPERATION COOLING OPERATION (COOLING OPERATION AND AUTOMATIC • A warm air circulating system is employed, and therefore it takes some time until the COOLING OPERATION) entire room is warmed up after the start of •...
  • Page 14 • When the warm air stays under the ceiling ADJUSTMENT and your feet are cold, we recommend that For programming TEMPERATURE, FAN you use a circulator (a fan to circulate the SPEED and AIRFLOW DIRECTION, follow air inside the room). For details, consult the procedure shown below.
  • Page 15 • It may take some time unit the airflow AUTOMATIC SWITCHING OF switch is completed, but this is normal. AIRFLOW DIRECTION • Fan speeds supported depend on the model that is connected. The air conditioner switches to automatic • In “ ”...
  • Page 16 Description of airflow direction Ceiling suspended Wall mounted Airflow settings and operation direction Up/down airflow Up/down airflow The range of movement of the airflow settings direction blades varies by indoor unit model. The airflow direction can be fixed in Consult the dealer of purchase for details. any position in the range Position 0 to Position 4.
  • Page 17 For example. PROGRAMMING TIMER When the timer is programmed to stop the system after 3 Press the PROGRAMMING TIMER hours and start the button and set the time for stopping or air conditioner after starting the air conditioner. 4 hours, the air conditioner will stop When this button is pressed, after 3 hours and then...
  • Page 18 Outdoor unit B. When the COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH is not Indoor unit provided Using the wireless remote controller, first follow the below procedure to assign the privilege to set cool/heat operations for COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH other units to a indoor unit. Outdoor unit Outdoor unit BS unit...
  • Page 19 To switch the operation using the wireless remote controller, point it at the indoor unit to which cool/heat selection privilege has been assigned. The operation of the indoor units without cool/heat selection privilege switches in accordance with the operation of the indoor unit assigned with cool/heat selection privilege.
  • Page 20: Operation Characteristics

    PRECAUTIONS FOR GROUP Remote controller CONTROL SYSTEM OR TWO NOTES REMOTE CONTROLLER CONTROL • Contact your Daikin dealer in case of SYSTEM changing the combination or setting of group control and two remote controller This system provides two other control control systems.
  • Page 21: Not Malfunction Of The Air Conditioner

    • Check if the indoor unit number and 11. NOT MALFUNCTION OF wireless remote controller number THE AIR CONDITIONER are equal. Refer to the operation manual attached to For example. the indoor unit. And the following symptoms do not indicate air conditioner malfunction Number Number I.
  • Page 22 EMERGENCY STOP When the air conditioner stops in emergency, the OPERATING Press PROGRAMMING TIMER button INDICATOR LAMP on the indoor unit and change the unit number. starts blinking. Take the following steps yourself to Press to change the unit number until the read the malfunction code that appears indoor unit beeps and perform the following on the display.
  • Page 23: How To Check The Initial Set Value

    Press the button 2 times to Reset of the display return to normal operation mode. Press the OPERATION MODE SELECTOR button to get the display back to the normal state. [Trouble] The OPERATING INDICATOR LAMP of the indoor unit is flashing and the unit does not work at all.