Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air
conditioner. It will tell you how to use the unit properly and
help you if any trouble occurs. After reading the manual, file
it away for future reference.

OPERATION MANUAL

Advertisement

loading

Summary of Contents for Daikin BRC7E63W

  • Page 1: Operation Manual

    MODELS BRC7E63W BRC7E66 Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file...
  • Page 2: Table Of Contents

    PRIOR TO USE This operation manual is exclusively for instructions on how to use the wireless remote controller. Read also the operation manual attached to the indoor unit and to the outdoor unit for safe usage of the system and maintenance. The air conditioner corresponding to this controller comes under the term “appliances accessible to the general public”.
  • Page 3 ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH 21 20...
  • Page 4: Safety Considerations

    Ask your dealer to perform servicing 1. SAFETY CONSIDER- or repairs whenever necessary. ATIONS Improper servicing or repairs could cause water leakage, electric shocks or fire. Read the following cautions carefully and Do not stick your fingers or any other use your equipment properly.
  • Page 5: Names And Functions Of The Operating Section

    TEMPERATURE SETTING BUTTON 2. NAMES AND FUNCTIONS Use this button for SETTING TEMPER- OF THE OPERATING SEC- ATURE (Operates with the front cover TION (Fig. 1, 2) of the remote controller closed.) PROGRAMMING TIMER BUTTON DISPLAY “ ” (SIGNAL Use this button for programming TRANSMISSION) “START and/or STOP”...
  • Page 6: Handling For Wireless Remote Controller

    AIR FILTER CLEANING TIME 3. HANDLING FOR INDICATOR LAMP (Red) WIRELESS REMOTE Lights up when it is time to clean the air CONTROLLER filter. DEFROST LAMP (Orange) Precautions in handling remote con- Lights up when the defrosting opera- troller tion has started. (For straight cooling Direct the transmitting part of the remote type this lamp does not turn on.) controller to the receiving part of the air...
  • Page 7: Operation Procedure

    Pull it upward If the indoor unit is under centralized control, it is necessary to switch the remote controller’s setting. In this case, contact your DAIKIN dealer. 4. OPERATION PROCEDURE Refer to figure 1 on page [1] Remote • Operating procedure varies with heat controller pump type and cooling only type.
  • Page 8 〈〈 〈〈 〈〈 〈〈FOR SYSTEMS WITHOUT COOL/ OPERATION MODE HEAT CHANGEOVER REMOTE SELECTOR CONTROL SWITCH〉〉 〉〉 〉〉 〉〉 Refer to figure 1-1, 2 on page [1] (1) Select OPERATION MODE with the COOL/HEAT CHANGEOVER REMOTE OPERATION MODE MODE CONTROL SWITCH as follows. SELECTOR COOLING OPERATION .....
  • Page 9 • As the frost on the coil of an outdoor unit In case of automatic operation increase, heating effect decreases and the Each time this button is pressed, system goes into DEFROST OPERATION. setting temperature shifts to “H” • The fan operation stops and the side.
  • Page 10 A. UP AND DOWN DIRECTION on parts in the air discharge outlet from • The movable limit of the flap is change- dripping. able. Contact your Daikin dealer for details. • Operation mode includes automatic operation. Press the AIR FLOW DIRECTION ADJUST button to select the air direc- B.
  • Page 11 HOW TO SET MASTER PROGRAMMING TIME REMOTE CONTROLLER DOWN (For VRV system) Press the PROGRAMMING TIME but- ton and set the time for stopping or • When the system is installed as shown starting the system. below, it is necessary to designate the master remote controller.
  • Page 12 When the indoor unit with master remote EMERGENCY OPERATION controller is set to “COOL”, you can switch over operation mode between “FAN”, “DRY” When the remote controller does not work and “COOL”. due to battery failure or the absence thereof, When the indoor unit with master remote use this switch which is located beside the controller is set to “HEAT”, you can switch...
  • Page 13: Not Malfunction Of The Air Conditioner

    • Only the operating indicator lamp out of 3 other lamps on the indoor unit display functions. NOTE • Contact your Daikin dealer in case of 6. HOW TO DIAGNOSE changing the combination or setting of TROUBLE SPOTS group control and two remote controller control systems.
  • Page 14 Press until the indoor unit makes a long beep. The malfunction code is fixed when the DOWN indoor unit makes a long beep. Press PROGRAMMING TIMER BUT- TON and change the unit number. MODE Reset of the display Press to change the unit number until the indoor unit beeps and perform the following Press OPERATION MODE SELECTOR operation according to the number of beeps.
  • Page 15 Trouble] The RUN lamp of the indoor unit is flashing and the unit does not work at all. Malfunction Code Unit No. which sensed trouble ON OFF Nnmber TEMP TIME CODE DOWN Operate the indoor unit with the remote con- RESERVE CANCEL UNIT N troller of the same number.
  • Page 16 3PA63363-21T EM00A046 (0101) HT...