12. Troubleshooting
Malfunction
Possible cause
No hydraulic oil pressure at hydraulic
Pump does not deliver
lubricant
connection
Pressure spring broken
Delivery rate adjusted to 0,0 cm³/stroke
Cartridge empty
Sealing to cartridge leaky
Counter pressure in lubrication system
too high (line rest pressure too high)
Delivery rate adjusted wrong
Lubricant quantity too
low or too high
...a product of
Possible remedy
Check the pressure at the hydraulic connection
Renew pressure spring
Adjust delivery rate
Change cartridge
Renew sealing
Check lubrication system
Adjust delivery rate
Page 11
© BEKA 2015 All rights reserved!
Need help?
Do you have a question about the HPM-2S and is the answer not in the manual?