3-4. Setting Items of the Secondary
Station
Common Items
Name Display and Name Input Method:
Name displayed for the source or destination will automat-
ically switch depending on the state of the primary station
menu "J: NAME STYLE" is (Type + Num) or
(DESCRIP.NAM).
Compatibility of the Type + Num and DESCRIP.NAME
can be confirmed with "S: DISPLAY DESCRIPTION
NAME". To use the description name, the terminal name
needs to be sent to the panel beforehand from "N: SET
DESCRIPTION NAME GROUP" in the primary station
menu.
When it is "Type + Number" name mode (Type + Num):
. Name of destination or source is displayed by "Type
name + Number".
. Select the name from the type name list displayed at the
bottom of the screen and input the number using the
number key to change/modify the name.
When it is Description name mode (DESCRIP.NAME):
. Name of destination or source is displayed by "Descrip-
tion" name.
. Name can be set/changed by the same method as Type +
Num (default), but it is possible to directly input the
description name using alphabet keys and number keys
by pressing [Ctrl] _ [N].
3-8
H : SET PHANTOM TABLE
Purpose
This menu is used to set PHANTOM which switchers
several crosspoints, using the source selection button of the
remote control unit.
The total number of cross-points that can be set to phantom
is 64.
Setting Procedure
1. Select menu item of the secondary station [H].
2. Select an item using the cursor, enter the phantom
name, the destination name and the source name.
3. When [Enter] is pressed, the phantom table can be set.
If [Enter] is pressed before setting, the registration
will be deleted.
4. Input the data to the phantom table. The phantom
function consists of the global phantom function regis-
tered at the primary station, the normal type of local
phantom function registered at each remote control unit
and the destination off set type of local phantom function.
. . . . . Setting the Global Phantom Function
Input the phantom name with the type name and the number.
Next, press [G] at destination name position. Lastly, input the
global phantom number (four digits) set at the primary station.
. . . . . Setting the Normal Type of Local Phantom
Function
1) At [J : NAME STYLE (Type + Num)] in the
primary station menu item [J], input the type name
(between 0 and F) and the number for the phantom
name, destination name, source name and level
number respectively. (When the remote control unit
button is pressed, crosspoints with the same phan-
tom name will be switched together.)
2) At [J : NAME STYLE (DESCRIP. NAME)] in the
primary station menu item [J], input the phantom name
and level number in the same way as 1). For the source
name and destination name, the Description name and
"Type + Number" name can be selected freely.
Each time [Ctrl] _ [N] are pressed, the Description
name input mode (Crrl-N: DESCRIP. NAME) and
"Type + Number" name input mode (Crrl-N: Type
+ Num) will be switched alternately.