Adjustment procedure:
1.
AUTO W/B BAL switch (front panel) → BLACK
(Execute black balance auto adjustment.)
2.
Make the following settings with the menu.
MENU: MAINTENANCE
PAGE: Preset White
ITEM: Color Temp <P>:3200 K
ITEM: Color Temp Balance <P>:?0
MENU: PAINT
PAGE: Switch Status
ITEM: Gamma → Off
ITEM: Detail → Off
3.
Select line at the center with the waveform monitor.
4.
Set the waveform monitor to the CHROMA mode.
5.
Measuring equipment: Waveform monitor
Adjusting point: Make the following adjustments with the menu.
MENU: SERVICE
PAGE: CCD adjustment
ITEM: R CCD GAIN
ITEM: B CCD GAIN
Specification: Adjust the CCD gain alternately to minimize carrier leak C.
Settings after adjustment
• Make the following settings with the menu.
MENU: PAINT
PAGE: Switch Status
ITEM: Gamma → On
ITEM: Detail → On
White Shading Adjustment
The white Shading menu enables the adjustment of the horizontal and vertical Saw correction level and parabola