Changinge the RO Membrane
1.
Place the unit on its back
2.
Unscrew the two screws on front and remove the bottom black plastic
cover.
3.
Remove the remaining two screws on the bottom plate and remove the
plate.
4.
Unscrew the clamp fixing on bottom of the membrane housing.
5.
Remove the black plastic cap.
Use a big screwdriver for support.
`
6.
Pull the membrane out and replace with a new membrane.
The RO-membrane has an imprint indicating the flow direction,
`
the arrow must point upwards.
The rubber seal must always be at the bottom
`
7.
Re-assemble the system vise-versa.
Changinge the DI resin filter.
1. Unscrew the right filter cartridge with the filter key
and dump the water.
2. Remove the resin filter.
3. Insert the new filter the right way round (blue insert up).
If it is the wrong way round, water cannot flow through
and backwater will occur.
4. Screw in the cartridge again to the unit and fix it with the filter key.
The filter cartridge is replaced.