5.2 Cleaning surfaces with the HydroPower RO S

The HydroPower RO S has two water out modes: PURE and TAP BOOST.
PURE: This mode is used for spotless cleaning of windows and facades and gives out up to 180l/h of pure
water with 4 bar (at 18°C water temperature with a 1/2" hose).
TAP BOOST: The boost function allows a strong tap water-jet on demand for prewashing of heavy soiled or
horizontal surfaces. It will also remove cobwebs and dirt from corners that cannot be reached with a
brush. It delivers up to 1.000l/h of tap water with 8-10 bar.

5.3 Interruption of work

If you need to interrupt your work with the HydroPower RO S, you can switch off the device by setting the
lower switch to OFF. You can also control the unit by the water pressure:
The pump control switches off automatically after some seconds in case of
negative pressure. To start it again, press the red RESTART-button at the pump
control for at least 5 seconds.
Example 1: You switch off the tap water line:
The pump stopps after about 30 seconds.
When you switch the tap water line on again, you have to press the red RESTART
button at the pump control on backside for about 5 seconds. Try if the pump
stays running. If not, repeat pressing the button again for 5 seconds as long as enough water is in the
system and the pump runs continuously.
Example 2: You interrupt the water consumption at the water fed pole.
In this case the pump will stop after about 10 seconds. After opening the water line again, the pump
starts to work again immedialtely.
NOTE
The longer the hose from the water outlet to the water fed pole, the larger the
diameter of the hose should be.
NOTE
As long as the HydroPower RO S is connected to water but not switched on, no
water runs through the system because the „TAP BOOST" and „PURE" valves are
closed.