HydroPower® RO S
Commissioning
4.4.1
Commissioning of new or preserved HydroPower RO S:
The pre-filter and the resin filter are not inserted in new or preserved units, as they must not come
into contact with the diaphragm care agent.
Before using the resin filter, the membrane maintenance agent must be completely rinsed out.
1. Open the water line and start the HydroPower RO S by setting the upper
switch to „RO FLUSH" and the lower switch to „PURE". Rinse out the
membrane care agent for about 15 minutes.
2. Switch off the HydroPower RO S: turn the lower switch to OFF.
3. Disconnect the water supply.
4. Unscrew the resin cartridge and insert the resin filter (RORE2).
Make sure that the orientation is correct, the blue filter inlet must be on
top!
5. Screw the cartridge back on with help of the included filter key.
6. Start the HydroPower RO S by setting upper switch to WORK and lower
switch to PURE.
The HydroPower RO S is now ready for use.
3
1
2
4
5
19