5.4 Switching off the HydroPower RO S

To switch off the HydroPower RO S after finishing the work, proceed as
follows:
1. For a longer service life, the membrane should be flushed for
approx. 5 minutes after work.To do this, set the upper rotary switch to
„RO FLUSH" and the lower switch to „PURE".
Info: During this process, pure water continues to be dispensed to the
`
bar in a slightly reduced quantity. You can therefore continue to work
while doing this.
2. Switch off the unit with the lower switch.
3. Disconnect the power supply and the water supply.
4. Remove the hoses from the front connections.
The HydroPower RO S is switched off and can be transported.
3

Malfunctions

6

Procedure for accidents

6.1
Turn the lower switch of the HydroPower RO S to OFF to turn off the system:
• In case of danger of injury,
• Risk of damage to the HydroPower RO S.
In the event of an accident, take immediate action and call the local emergency number.

Procedure for malfunctions

6.2
During operation, the following faults may occur:
Water pressure too low
The inlet pressure from the water pipe is too low to provide the desired filter
`
performance.
The pump switches off.
Check whether the inlet hose is kinked or if there is too little pressure on the water pipe.
`
To start the pump, press the red RESTART button on the backside of the housing for
`
about 5 seconds.
Overpressure
Overpressure can occur if the water pressure from the pipe is more than 6 bar.
To check the water pressure in the pipe, proceed as follows:
The pressure gauge indicates the line pressure.
`
As soon as the pump is switched on, the pressure increases by 4 bar. If the inlet
`
pressure is too high, connect a pressure reducer to the water inlet and regulate
the pressure down.