1
[2-5-2] USBA ASSY,
A
MAIN ASSY

Disconnect the connector and then remove
the USBA ASSY (with the Stay).

Remove the screw (BBZ30P060FTB) and
then remove the USBA ASSY from the Stay
(DNF1987).
B

Remove the three screws (BBZ30P060FTB)
and then remove the Sheet (DEC3702).
(Refer to the "[2-2-3] Sheet (DEC3702)")

Disconnect the two connectors.

Remove the three screws. (BBZ30P060FTB)
Note on assembling
∗13: Screws must be attached so as to leave a
gap of about 0.5 mm between the MAIN
ASSY and IO ASSY.
C

Remove the MAIN ASSY.
Note: MAIN ASSY is affixed to the Chassis with
the Heat Cond Sheet.

Remove the Heat Cond Sheet and Knob
(DNK6607) from the MAIN ASSY.
D
[3] Folding and Connecting the FFCs
When replacing the FFCs (DDD1753,
DDD1759, DDD1760, DDD1763), fold
them to make right angles as shown by
the guide lines on the silk of the PCBs
E
(side-B).
Lay the FFCs the contact sides facing the
bottom along the broken lines and
non-contact sides facing the bottom along
the solid lines.
Three marks indicate the places where
FFCs should be connected before
attachment the Shield Sheet.
Take care not to reverse the process,
which may affect the performance.
F
56
1
2
Front
IO ASSY
Front
Knob (DNK6607)
Guideline for
FFC (DDD1759)
Front
SEQ1 ASSY
Guideline for
FFC (DDD1763)
TSP-16
2
3
1
USBA ASSY
CN7601
∗13
4
CN3
MAIN ASSY
4
CN4
6
5
Chassis
7
Heat Cond Sheet
MAIN ASSY (side-B)
7
Guideline for
FFC (DDD1760)
PADB ASSY
3
4
2
USBA ASSY
Stay (DNF1987)
5
5